Functional cellular assays with multiparametric silicon sensor chips
The DOI matches its Crossref record.
Abstract
Multiparametric silicon sensor chips mounted into biocompatible cell culture units have been used for investigations on cellular microphysiological patterns. Potentiometric, amperometric and impedimetric microsensors are combined on a common cell culture surface on the chip with an area of approximately 29 mm2. Extracellular acidification rates (with pH-sensitive field effect transistors, ISFETs), cellular oxygen consumption rates (with amperometric electrode structures) and cell morphological alterations (with impedimetric electrode structures, IDES) are monitored on single chips simultaneously for up to several days. The corresponding test device accommodates six of such sensor chips in parallel, provides electronic circuitry and maintains the required cell culture conditions (temperature, fluid perfusion system). Sensor data are transformed into quantitative information about microphysiologic conditions. The outcome of this transformation as well as reliability and sensitivity in detection of drug effects is discussed. This is the first report on multiparametric cell based assays with data obtained solely with integrated sensors on silicon chips. Those assays are required in different fields of application such as pharmaceutical drug screening, tumor chemosensitivity tests and environmental monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Organic field-effect transistor-based flexible sensors
Yuvaraja, S., Nawaz, A., Liu, Q., Dubal, D., Surya, S. G., Salama, K. N., & Sonar, P. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00811j · Cited by 386
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Weltin, A., Slotwinski, K., Kieninger, J., Moser, I., Jobst, G., Wego, M., Ehret, R., & Urban, G. A. (2014) · Lab Chip · doi:10.1039/c3lc50759a · Cited by 263
A multicellular spheroid array to realize spheroid formation, culture, and viability assay on a chip
Torisawa, Y.-S., Takagi, A., Nashimoto, Y., Yasukawa, T., Shiku, H., & Matsue, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.054 · Cited by 176
Cell-based electrochemical biosensors for water quality assessment
Lagarde, F., & Jaffrezic-Renault, N. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4816-7 · Cited by 164
Torisawa, Y.-S., Shiku, H., Yasukawa, T., Nishizawa, M., & Matsue, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.028 · Cited by 124
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- Brischwein, M., Motrescu, E. R., Cabala, E., Otto, A. M., Grothe, H., & Wolf, B.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2003
- Volume
- 3
- Issue
- 4
- Pages
- 234
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2091993202
- Cited by
- 134
- References
- 0
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.