Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 463

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Magnesium isotope heterogeneity of the isotopic standard SRM980 and new reference materials for magnesium-isotope-ratio measurements

Galy, Albert, Yoffe, Olga, Janney, Philip E., Williams, Ross W., Cloquet, Christophe, Alard, Olivier, Halicz, Ludwik, Wadhwa, Meenakshi, Hutcheon, Ian D., Ramon, Erick, Carignan, Jean·2003·Journal of Analytical Atomic Spectrometry

Abstract

Multicollector ICP-MS has been used for the precise measurement of variations in the isotopic composition of the isotopic standard of magnesium (SRM980) provided by the National Institute of Standards and Technology (Gaithersburg, MD, USA). The SRM980 consists of metal chips weighing between 1 and 50 mg and each unit delivered by the National Institute of Standards and Technology corresponds to a bottle containing about 0.3 g. Height units were analysed. Variations in sample 25Mg/24Mg, and 26Mg/24Mg ratios are expressed as δ25Mg and δ26Mg units, respectively, which are deviations in parts per 103 from the same ratio in a standard solution. The differences in δ25Mg and δ26Mg of the SRM980 are up to 4.20 and 8.19‰, respectively, while the long-term repeatability of δ25Mg and δ26Mg are 0.09 and 0.16‰, respectively, at 95% confidence. However, when plotted in a three-isotope diagram, all the data fall on a single mass fractionation line. Overall limits of error of the SRM980 reported here fall within the previously reported overall limits of error. The isotopic heterogeneity not only corresponds to differences among units but has been found at the chip-size level. This result, due to the precision of the MC-ICP-MS technique, makes the SRM980 inappropriate for the international isotopic standard of magnesium. The SRM980 can still be used to report the excess of 26Mg, which is defined by the deviation from the mass-dependent relationship between 25Mg/24Mg, and 26Mg/24Mg ratios. Two large batches (around 10 g of Mg in each) of pure Mg solutions (in 0.3 M HNO3) have been prepared and characterised. These 2 solutions (DSM3 and Cambridge 1) are suitable reference material because they are immune to heterogeneity. DSM3 and Cambridge 1 are isotopically different (by 1.3‰ per u) and are available upon request from the first author. In addition, DSM3 has an isotopic composition very similar to the Mg-isotopic composition of carbonaceous chondrites (Orgueil and Allende). Because of the lack of heterogeneity and the cosmochemical and geochemical significance of DSM3, we urge the use of DSM3 as the primary isotopic reference material to report Mg-isotopic variations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b309273a

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 463

Metadata

Authors
Galy, A., Yoffe, O., Janney, P. E., Williams, R. W., Cloquet, C., Alard, O., Halicz, L., Wadhwa, M., Hutcheon, I. D., Ramon, E., & Carignan, J.
Venue
Journal of Analytical Atomic Spectrometry
Published
2003
Volume
18
Issue
11
Pages
1352
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2128419417
Cited by
463
References
13
FWCI
5.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.