The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Determination of the Lewis acidity of ionic liquids by means of an IR spectroscopic probe
Abstract
Pyridine and ethanenitrile can be used as molecular probes to measure the Lewis acidities of ionic liquids by monitoring the shift of IR absorption bands near 1450 cm(-1) for pyridine and in the range 2250-2340 cm(-1) for ethanenitrile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Ionic Liquids for Clean Technology
Seddon, K. R. (1997) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199704)68:4<351::aid-jctb613>3.0.co;2-4 · Cited by 2,034
Novel Brønsted Acidic Ionic Liquids and Their Use as Dual Solvent−Catalysts
Cole, A. C., Jensen, J. L., Ntai, I., Tran, K. L. T., Weaver, K. J., Forbes, D. C., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja026290w · Cited by 1,197
Ionic liquids: applications in catalysis
Zhao, D., Wu, M., Kou, Y., & Min, E. (2002) · Catalysis Today · doi:10.1016/s0920-5861(01)00541-7 · Cited by 1,049
Self-citationNew developments in catalysis using ionic liquids
Gordon, C. M. (2001) · Applied Catalysis A: General · doi:10.1016/s0926-860x(01)00834-1 · Cited by 1,004
Determination of an Acidic Scale in Room Temperature Ionic Liquids
Thomazeau, C., Olivier-Bourbigou, H., Magna, L., Luts, S., & Gilbert, B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0297382 · Cited by 431
Fannin, A. A., King, L. A., Levisky, J. A., & Wilkes, J. S. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150656a037 · Cited by 156
Carlin, R. T., & Wilkes, J. S. (1990) · Journal of Molecular Catalysis · doi:10.1016/0304-5102(90)85135-5 · Cited by 141
Hsiu, S.-I., Huang, J., Sun, I., Yuan, C., & Shiea, J. (2002) · Electrochimica Acta · doi:10.1016/s0013-4686(02)00509-1 · Cited by 139
Cited by
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Hydrophobic deep eutectic solvents in microextraction techniques–A review
Makoś, P., Słupek, E., & Gębicki, J. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104384 · Cited by 469
Deep desulfurization of diesel fuel using ionic liquids: current status and future challenges
Kulkarni, P. S., & Afonso, C. A. M. (2010) · Green Chemistry · doi:10.1039/c002113j · Cited by 459
Overview of acidic deep eutectic solvents on synthesis, properties and applications
Qin, H., Hu, X., Wang, J., Cheng, H., Chen, L., & Qi, Z. (2020) · Green Energy & Environment · doi:10.1016/j.gee.2019.03.002 · Cited by 448
From Dysfunction to Bis‐function: On the Design and Applications of Functionalised Ionic Liquids
Fei, Z., Geldbach, T. J., Zhao, D., & Dyson, P. J. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200500581 · Cited by 383
Metadata
- Authors
- Yang, Y.-L., & Kou, Y.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Issue
- 2
- Pages
- 226
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2027467147
- Cited by
- 266
- References
- 10
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the Lewis acidity of ionic liquids by means of an IR spectroscopic probe. https://app.cochat.ai/papers/10.1039/b311615h
- The paper
- Yang, Y.-L., & Kou, Y. (2004). Determination of the Lewis acidity of ionic liquids by means of an IR spectroscopic probe. Chemical Communications. https://doi.org/10.1039/b311615h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.