Electrospray mass spectrometry of undiluted ionic liquidsThis manuscript has been authored by a contractor of the U.S. Government under contract No. DE-AC05-00OR22725. Accordingly, the U.S. Government retains paid-up, nonexclusive, irrevocable, worldwide license to publish or reproduce the published form of this contribution, prepare derivative works, distribute copies to the public, and perform publicly and display publicly, or allow others to do so, for U.S. Government purposes.
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Ionic liquids have been analyzed in undiluted form using electrospray mass spectrometry (ES-MS); results indicate that signal-to-noise ratios for minor constituents are comparable to those observed in conventional, diluted ES-MS and that this approach could be readily applied for mass spectrometric analysis of ionic liquids and ionic impurities/additives dissolved therein, especially those that are solvent reactive.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Besides, as a result of their low volatility and high viscosity, they are also incompatible with LC-MS systems, since the formation of the electrospray is highly affected, which redounds in serious matrix effects and signal drift [36,37].”
From Use of green alternative solvents in dispersive liquid‐liquid microextraction: A review (2022) · cites this paper as [37]
Citations
Cites
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Novel Electrochemical Studies of Ionic Liquids
Quinn, B. M., Ding, Z., Moulton, R., & Bard, A. J. (2002) · Langmuir · doi:10.1021/la011458x · Cited by 361
Romero-Sanz, I., Bocanegra, R., Fernandez de la Mora, J., & Gamero-Castaño, M. (2003) · Journal of Applied Physics · doi:10.1063/1.1598281 · Cited by 257
Suarez, P. A. Z., Selbach, V. M., Dullius, J. E. L., Einloft, S., Piatnicki, C. M. S., Azambuja, D. S., de Souza, R. F., & Dupont, J. (1997) · Electrochimica Acta · doi:10.1016/s0013-4686(96)00444-6 · Cited by 237
Electrospray as a Source of Nanoparticles for Efficient Colloid Thrusters
Gamero-Castano, M., & Hruby, V. (2001) · Journal of Propulsion and Power · doi:10.2514/2.5858 · Cited by 232
Organic salts, liquid at room temperature, as mobile phases in liquid chromatography
Poole, C. F., Kersten, B. R., Ho, S. S. J., Coddens, M. E., & Furton, K. G. (1986) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)83397-5 · Cited by 149
Enhanced ion conduction in imidazolium-type molten salts
Ito, K., Nishina, N., & Ohno, H. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00335-7 · Cited by 109
Abdul‐Sada, A. K., Greenway, A. M., Seddon, K. R., & Welton, T. (1993) · Organic Mass Spectrometry · doi:10.1002/oms.1210280706 · Cited by 75
Ford, W. T. (1975) · Analytical Chemistry · doi:10.1021/ac60357a071 · Cited by 13
Cited by
Biological Activity of Ionic Liquids and Their Application in Pharmaceutics and Medicine
Egorova, K. S., Gordeev, E. G., & Ananikov, V. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00562 · Cited by 1,649
Air and water stable ionic liquids in physical chemistry
Endres, F., & Zein El Abedin, S. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b600519p · Cited by 1,134
Halometallate ionic liquids – revisited
Estager, J., Holbrey, J. D., & Swadźba-Kwaśny, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60310e · Cited by 308
Ionic Liquids in Chemical Analysis
Koel, M. (2005) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340500304016 · Cited by 290
“Ionic liquids were analyzed in undiluted form [ 85 ], where results indicate that signal-to-noise ratios for minor constituents are comparable to those observed in conventional, diluted ES-MS and that this approach could be readily applied for mass spectrometric analysis of ILs and ionic impurities/additives dissolved…”
BackgroundIonic Liquids in Chemical Analysis
Rochefort, D. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9087693 · Cited by 248
Development of Cation/Anion “Interaction” Scales for Ionic Liquids through ESI-MS Measurements
Bini, R., Bortolini, O., Chiappe, C., Pieraccini, D., & Siciliano, T. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp0663199 · Cited by 193
Berthon, L., Nikitenko, S. I., Bisel, I., Berthon, C., Faucon, M., Saucerotte, B., Zorz, N., & Moisy, P. (2006) · Dalton Transactions · doi:10.1039/b601111j · Cited by 173
Use of green alternative solvents in dispersive liquid‐liquid microextraction: A review
Grau, J., Azorín, C., Benedé, J. L., Chisvert, A., & Salvador, A. (2022) · Journal of Separation Science · doi:10.1002/jssc.202100609 · Cited by 131
Large Aggregated Ions Found in Some Protic Ionic Liquids
Kennedy, D. F., & Drummond, C. J. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp900814y · Cited by 104
Oral delivery of sorafenib through spontaneous formation of ionic liquid nanocomplexes
Shi, Y., Zhao, Z., Gao, Y., Pan, D. C., Salinas, A. K., Tanner, E. E. L., Guo, J., & Mitragotri, S. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.03.018 · Cited by 98
Validation of Speciation Techniques: A Study of Chlorozincate(II) Ionic Liquids
Estager, J., Nockemann, P., Seddon, K. R., Swadźba‐Kwaśny, M., & Tyrrell, S. (2011) · Inorganic Chemistry · doi:10.1021/ic200586u · Cited by 93
Ionic liquids for mass spectrometry: Matrices, separation and microextraction
Abdelhamid, H. N. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.12.007 · Cited by 87
Molecular ions of ionic liquids in the gas phase
Gross, J. H. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.06.002 · Cited by 68
“Such observations were made by fast atom bombardment (FAB) [13], laser desorption/ion ization (LDI) [14], matrix-assisted laser desorption/ ionization (MALDI) [14-16], electrospray ionization (ESI) [ 17-20 ], and field desorption (FD) [21].”
MethodOptimal Molecular Design of Ionic Liquids for High-Purity Bioethanol Production
Chávez-Islas, L. M., Vasquez-Medrano, R. C., & Flores‐Tlacuahuac, A. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie101791t · Cited by 66
Ionic liquids enable electrospray ionisation mass spectrometry in hexane
Henderson, M. A., & McIndoe, J. S. (2006) · Chemical Communications · doi:10.1039/b606938j · Cited by 62
Wadekar, P. H., Khose, R. V., Pethsangave, D. A., & Some, S. (2019) · ChemSusChem · doi:10.1002/cssc.201900953 · Cited by 65
High performance NMR in ionic liquids
Giernoth, R., Bankmann, D., & Schlörer, N. E. (2005) · Green Chemistry · doi:10.1039/b417783e · Cited by 60
Shamshina, J. L., Zavgorodnya, O., & Rogers, R. D. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.13931-9 · Cited by 56
Uranyl Ion Extraction into Room Temperature Ionic Liquids: Species Determination by ESI and MALDI-MS
Murali, M. S., Bonville, N., & Choppin, G. R. (2010) · Solvent Extraction and Ion Exchange · doi:10.1080/07366299.2010.480928 · Cited by 49
“It is to be mentioned here that although the purification of RTILs was satisfactory, a component present in a purified RTIL to the order of 10-4M can also show a peak (in ESI-MS) aswas observed by Jackson et al.[38]Whenwe ran a blank with RTILs this particular peak of 82 was not positively identified.”
BackgroundThe vapour of imidazolium-based ionic liquids: a mass spectrometry study
Deyko, A., Lovelock, K. R. J., Licence, P., & Jones, R. G. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c1cp21821b · Cited by 48
Prince, B. D., Tiruppathi, P., Bemish, R. J., Chiu, Y., & Maginn, E. J. (2014) · The Journal of Physical Chemistry A · doi:10.1021/jp507073e · Cited by 51
Liquid injection field desorption/ionization-mass spectrometry of ionic liquids
Gross, J. H. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.09.019 · Cited by 39
“Indeed, analyses of ILs with MALDI [13], ESI [14–17], and FAB [18] have already been conducted, and those methods were found to serve nicely for the analysis of ILs.”
MethodGiernoth, R., & Bankmann, D. (2005) · European Journal of Organic Chemistry · doi:10.1002/ejoc.200500557 · Cited by 34
Development of Solvent-Free Ambient Mass Spectrometry for Green Chemistry Applications
Liu, P., Forni, A., & Chen, H. (2014) · Analytical Chemistry · doi:10.1021/ac500527q · Cited by 33
Borane-substituted imidazol-2-ylidenes: syntheses in vacuo
Taylor, A. W., Lovelock, K. R. J., Jones, R. G., & Licence, P. (2011) · Dalton Transactions · doi:10.1039/c0dt01240h · Cited by 30
Lu, Y., King, F. L., & Duckworth, D. C. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.02.017 · Cited by 27
“ES-MS analysis of tetrabutylammonium ions and neutral ferrocene ions in neat (undiluted) ILs has been investigated and was found to have sensitivity for these dissolved analytes comparable to the diluted ILs [19, 20].”
MethodSelf-citationRietzler, F., Piermaier, M., Deyko, A., Steinrück, H., & Maier, F. (2014) · Langmuir · doi:10.1021/la404429q · Cited by 25
Electrospray mass spectral fragmentation study of N,N′-disubstituted imidazolium ionic liquids
Lesimple, A., Mamer, O., Miao, W., & Chan, T. H. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.09.002 · Cited by 24
“To our knowledge, only a few published reports deal with ESMS of imidazole based ILs [8–11], and they incompletely describe their properties in the mass spectrometer and their fragmentation pathways.”
BackgroundNakamura, I. (2018) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.8b01465 · Cited by 24
Aggregation Behavior of Octyl Viologen Di[bis(trifluoromethanesulfonyl)amide] in Nonpolar Solvents
Marotta, E., Rastrelli, F., & Saielli, G. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp808306r · Cited by 23
Gross, J. H. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7720-0 · Cited by 22
Mass spectral evaluation of column bleeding for imidazolium-based ionic liquids as GC liquid phases
Шашков, М. В., & Sidelnikov, V. N. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6020-9 · Cited by 21
MAS NMR Investigation of Molecular Order in an Ionic Liquid Crystal
Mann, S. K., Devgan, M., Franks, W. T., Huband, S., Chan, C. L., Griffith, J. A., Pugh, D., Brooks, N. J., Welton, T., Pham, T. N., et al. (2020) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.0c02328 · Cited by 20
Silva, M. D., Brown, A. C., & Patrick, A. L. (2020) · Journal of Mass Spectrometry · doi:10.1002/jms.4518 · Cited by 19
Rencurosi, A., Lay, L., Russo, G., Prosperi, D., Poletti, L., & Caneva, E. (2007) · Green Chemistry · doi:10.1039/b615392e · Cited by 19
Sakhalkar, M., Aduri, P., Lande, S. V., & Chandra, S. (2019) · Clean Technologies and Environmental Policy · doi:10.1007/s10098-019-01769-y · Cited by 17
Lv, Y., Bai, H., Yang, J., He, Y., & Ma, Q. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00597 · Cited by 16
Lv, Y., Bai, H., He, Y., Yang, J., & Ma, Q. (2020) · Talanta · doi:10.1016/j.talanta.2020.120929 · Cited by 16
Tolstogouzov, A. B., Bardi, U., Nishikawa, O., & Taniguchi, M. (2008) · Surface and Interface Analysis · doi:10.1002/sia.2906 · Cited by 16
Patrick, A. L. (2019) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8587 · Cited by 15
Viradiya, R. A., Patel, N., Aswal, V. K., Patel, V. K., & Panjabi, S. H. (2023) · Langmuir · doi:10.1021/acs.langmuir.3c01257 · Cited by 11
Kitaoka, S., Nobuoka, K., Ishikawa, Y., & Wakisaka, A. (2008) · Analytical Sciences · doi:10.2116/analsci.24.1311 · Cited by 10
Viradiya, R. A., Aswal, V. K., Patel, N., Patel, V. K., Solanki, J. D., Soni, S. S., Vashi, A., & Panjabi, S. H. (2024) · Colloid & Polymer Science · doi:10.1007/s00396-024-05362-8 · Cited by 9
Zhou, W., Liu, J., Chambreau, S. D., & Vaghjiani, G. L. (2022) · Physical Chemistry Chemical Physics · doi:10.1039/d2cp01571d · Cited by 9
Zarzana, C. A., Groenewold, G. S., Benson, M. T., Delmore, J. E., Tsuda, T., & Hagiwara, R. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-2006-y · Cited by 9
Terhune, K. J., King, L. B., Prince, B. D., Jain, N. J., & Hawkett, B. S. (2016) · AIAA/SAE/ASEE Joint Propulsion Conference (JPC) · doi:10.2514/6.2016-4550 · Cited by 9
Groenewold, G. S., Delmore, J. E., Benson, M. T., Tsuda, T., & Hagiwara, R. (2013) · The Journal of Physical Chemistry A · doi:10.1021/jp407872c · Cited by 8
Ionic Liquid Matrices for Mass Spectrometry: Design, Synthesis, and Applications
Abdelhamid, H. N., & Wu, H. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.11016-9 · Cited by 6
Walton, B. L., Joshi, U., Dzyuba, S. V., Youngblood, W. J., & Verbeck, G. F. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6653 · Cited by 7
Nousiainen, M., Tolstogouzov, A. B., Holopainen, S., Jänis, J., & Sillanpää, M. E. T. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5143 · Cited by 6
Huber, S., Harder, M., Weidacher, N., Erharter, K., Kreutz, C., Schottenberger, H., Bonn, G. K., & Rainer, M. (2021) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.117669 · Cited by 5
Structures, properties and applications of bimetallic composite ionic liquids
Zhang, Y., Wu, L. Y., Zhang, R., Meng, X., Liu, H., Liu, Z., & Xu, C. (2021) · Scientia Sinica Chimica · doi:10.1360/ssc-2021-0099 · Cited by 5
Gutowska, N., & Maciejewski, A. (2014) · RSC Advances · doi:10.1039/c4ra03868a · Cited by 5
Elucidating gas phase microstructures of therapeutic deep eutectic systems
Olawuyi, O., Stewart, J., Sakib, M. M. H., Bryant, W., Wewers, M.-K., Lewit, N., Ali, M., Rahman, M. S., & Halim, M. A. (2025) · The Analyst · doi:10.1039/d4an00645c · Cited by 4
Unnatural Amino Acid‐Based Ionic Liquid Enables Oral Treatment of Nonsense Mutation Disease in Mice
Shi, Y., Shi, N., Yang, Y., Zheng, Z., & Xia, Q. (2024) · Advanced Science · doi:10.1002/advs.202306792 · Cited by 6
Electrospray Plume Divergence: Background Pressure Influence
Breddan, M. J. D., & Wirz, R. E. (2024) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2024.106417 · Cited by 4
Iron Fluoroanions and Their Clusters by Electrospray Ionization of a Fluorinating Ionic Liquid
Zarzana, C. A., Groenewold, G. S., Benson, M. T., Delmore, J. E., Tsuda, T., & Hagiwara, R. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1160-8 · Cited by 4
The effects of magnetic surface stress on electrospray of an ionic liquid ferrofluid
Terhune, K. J., King, L. B., Prince, B. D., Jain, N. J., & Hawkett, B. S. (2016) · AIAA/SAE/ASEE Joint Propulsion Conference (JPC) · doi:10.2514/6.2016-4549 · Cited by 3
Ionic liquid-based liquid-phase microextraction techniques
Azorín, C., Benedé, J. L., & Chisvert, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823334-4.00006-0 · Cited by 4
Meng, X., Xu, C., Han, Y., Liu, Z., Zhang, Y., Zhang, R., Huang, L., Ouyang, P., & Shi, Q. (2020) · Scientia Sinica Chimica · doi:10.1360/ssc-2020-0028 · Cited by 2
In situ study of ionic liquid Taylor cones using electron microscopy
Terhune, K. J., King, L. B., He, K., & Cumings, J. (2013) · AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit · doi:10.2514/6.2013-3822 · Cited by 2
Gutowska, N., & Maciejewski, A. (2016) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2016.06.010 · Cited by 2
Kitaoka, S., Nobuoka, K., & Ishikawa, Y. (2009) · Journal of Synthetic Organic Chemistry Japan · doi:10.5059/yukigoseikyokaishi.67.833 · Cited by 2
In situ visualization of ionic liquid electrospray emission using transmission electron microscopy
Terhune, K. J., King, L. B., He, K., & Cumings, J. (2013) · Cited by 2
Ionic Liquids in Green Sample Preparation
Mastellone, G., Marengo, A., Sgorbini, B., Rubiolo, P., & Cagliero, C. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839166419-00179 · Cited by 1
Cai, Y. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Spectroscopic techniques using ionic liquids
Bhawna, B., Dhingra, D., & Pandey, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823334-4.00005-9
Matsuda, T., & Chen, L. C. (2024) · Mass Spectrometry · doi:10.5702/massspectrometry.a0148
Zhou, W., Liu, J., Chambreau, S. D., & Vaghjiani, G. L. (2024) · Physical Chemistry Chemical Physics · doi:10.1039/d4cp02329c
Metadata
- Authors
- Jackson, G. P., & Duckworth, D. C.
- Affiliations
- Oak Ridge National Laboratory (US)
- Corresponding author
- Duckworth, Douglas C.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Issue
- 5
- Pages
- 522
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W1683213088
- Cited by
- 69
- References
- 11
- Citations by year
- 2025: 1 · 2024: 5 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 5 · 2019: 4 · 2018: 3 · 2017: 1 · 2016: 4 · 2015: 2 · 2014: 6 · 2013: 5 · 2012: 1
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Chemical Communications (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- ionic liquids, signal-to-noise ratio, minor components, ionic impurities, additives, solvent reactivity, mass spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.