The DOI matches its Crossref record.
Molded polyethylene glycol microstructures for capturing cells within microfluidic channels
Abstract
The ability to control the deposition and location of adherent and non-adherent cells within microfluidic devices is beneficial for the development of micro-scale bioanalytical tools and high-throughput screening systems. Here, we introduce a simple technique to fabricate poly(ethylene glycol)(PEG) microstructures within microfluidic channels that can be used to dock cells within pre-defined locations. Microstructures of various shapes were used to capture and shear-protect cells despite medium flow in the channel. Using this approach, PEG microwells were fabricated either with exposed or non-exposed substrates. Proteins and cells adhered within microwells with exposed substrates, while non-exposed substrates prevented protein and cell adhesion (although the cells were captured inside the features). Furthermore, immobilized cells remained viable and were stained for cell surface receptors by sequential flow of antibodies and secondary fluorescent probes. With its unique strengths in utility and control, this approach is potentially beneficial for the development of cell-based analytical devices and microreactors that enable the capture and real-time analysis of cells within microchannels, irrespective of cell anchorage properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Self-citationControlling the Porosity and Microarchitecture of Hydrogels for Tissue Engineering
Annabi, N., Nichol, J. W., Zhong, X., Ji, C., Koshy, S., Khademhosseini, A., & Dehghani, F. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0639 · Cited by 1,308
Self-citationMicroengineered hydrogels for tissue engineering
Khademhosseini, A., & Langer, R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.021 · Cited by 830
Self-citationModular tissue engineering: engineering biological tissues from the bottom up
Nichol, J. W., & Khademhosseini, A. (2009) · Soft Matter · doi:10.1039/b814285h · Cited by 567
Self-citationMicrofluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Metadata
- Authors
- Khademhosseini, A., Yeh, J., Jon, S., Eng, G., Suh, K. Y., Burdick, J. A., & Langer, R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 5
- Pages
- 425
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2121484578
- Cited by
- 200
- References
- 0
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molded polyethylene glycol microstructures for capturing cells within microfluidic channels. https://app.cochat.ai/papers/10.1039/b404842c
- The paper
- Khademhosseini, A., Yeh, J., Jon, S., Eng, G., Suh, K. Y., Burdick, J. A., & Langer, R. (2004). Molded polyethylene glycol microstructures for capturing cells within microfluidic channels. Lab on a Chip. https://doi.org/10.1039/b404842c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.