The DOI matches its Crossref record.
Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Abstract
A method to continuously separate different particle types in a suspension is reported. Acoustic forces in a standing wave field were utilized to discriminate lipid particles from erythrocytes in whole blood. The presented technology proposes a new method of cleaning, i.e. removing lipid emboli from, shed blood recovered during cardiac surgery. Blood contaminated with lipid particles enter a laminar flow micro channel. Erythrocytes and lipid particles suspended in blood plasma are exposed to a half wavelength standing wave field orthogonal to the direction of flow as they pass through the channel. Because of differences in compressibility and density the two particle types move in different directions, the erythrocytes towards the centre of the channel and the lipid particles towards the side walls. The end of the channel is split into three outlet channels conducting the erythrocytes to the centre outlet and the lipid particles to the side outlets due to the laminar flow profile. The separation channel was evaluated in vitro using polyamide spheres suspended in water, showing separation efficiencies approaching 100%. The system was also evaluated on whole blood using tritium labelled lipid particles added to bovine blood. More than 80% of the lipid particles could be removed while approximately 70% of the erythrocytes were collected in one third of the original fluid volume. The study showed that the further reduced micro channel dimensions provided improved performance with respect to; (i) separation efficiency, (ii) actuation voltage, and (iii) volumetric throughput as compared to earlier work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustofluidics 7: The acoustic radiation force on small particles
Bruus, H. (2012) · Lab on a Chip · doi:10.1039/c2lc21068a · Cited by 1,019
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Laurell, T., Petersson, F., & Nilsson, A. (2007) · Chem. Soc. Rev. · doi:10.1039/b601326k · Cited by 874
Self-citationBioprospecting for hyper-lipid producing microalgal strains for sustainable biofuel production
Mutanda, T., Ramesh, D., Karthikeyan, S., Kumari, S., Anandraj, A., & Bux, F. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2010.06.077 · Cited by 471
Microalgal species for sustainable biomass/lipid production using wastewater as resource: a review
Wu, Y.-H., Hu, H.-Y., Yu, Y., Zhang, T.-Y., Zhu, S.-F., Zhuang, L.-L., Zhang, X., & Lu, Y. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.02.026 · Cited by 155
Metadata
- Authors
- Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 129
- Issue
- 10
- Pages
- 938-943
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2042804367
- Cited by
- 330
- References
- 0
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels. https://app.cochat.ai/papers/10.1039/b409139f
- The paper
- Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004). Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels. The Analyst. https://doi.org/10.1039/b409139f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.