8-Hydroxyquinoline–chloroform single drop microextraction and electrothermal vaporization ICP-MS for the fractionation of aluminium in natural waters and drinks
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new method of cycle-flow single drop microextraction (SDME) combined with electrothermal vaporization (ETV)-ICP-MS was proposed for the fractionation of aluminium with 8-hydroxyquinoline (8-HQ) as extractant. Several factors affecting the separation of aluminium species, such as sample flow rate, microdrop volume, pH and extraction time were investigated, and the optimized microextraction conditions were established. The experimental results indicated that in a pH range of 5.0–7.5 labile monomeric Al species (free Al (Al3+, AlOH2+, and Al(OH)2+)) could be extracted by the 8-HQ–chloroform microdrop while non-labile monomeric Al species (Al–citrate, Al–SO4, Al–F, Al–EDTA, Al–humic) directly passed through the microdrop. Labile aluminium in the post-extraction organic phase was directly determined by ETV-ICP-MS. The total Al was determined using pneumatic nebulization (PN)-ICP-MS. The non-labile aluminium was obtained by subtraction of labile aluminium from the total aluminium. Under the optimized conditions, the detection limit of the method was 3.3 pg mL−1 and the relative standard deviation for 1 ng mL−1 of Al was 10%. After 8 min of extraction, the enrichment factor was 210. The proposed method has been successfully applied to the determination of Al species in natural water, coffee and tea infusions. The results were comparable with that obtained by the 8-HQ loaded silanized silica gel microcolumn system and conventional liquid–liquid extraction system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Zeini Jahromi, E., Bidari, A., Assadi, Y., Milani Hosseini, M. R., & Jamali, M. R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.007 · Cited by 398
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Metadata
- Authors
- Xia, L., Hu, B., Jiang, Z., Wu, Y., Li, L., & Chen, R.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 20
- Issue
- 5
- Pages
- 441-446
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2016020401
- Cited by
- 101
- References
- 2
- FWCI
- 9.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 8-Hydroxyquinoline–chloroform single drop microextraction and electrothermal vaporization ICP-MS for the fractionation of aluminium in natural waters and drinks. https://app.cochat.ai/papers/10.1039/b416938g
- The paper
- Xia, L., Hu, B., Jiang, Z., Wu, Y., Li, L., & Chen, R. (2005). 8-Hydroxyquinoline–chloroform single drop microextraction and electrothermal vaporization ICP-MS for the fractionation of aluminium in natural waters and drinks. J. Anal. At. Spectrom. https://doi.org/10.1039/b416938g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.