Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microfluidic devices are increasingly used to perform biological experiments on a single-cell basis. However, long-term stability of cell positions is still an issue. A novel biocompatible method for cell entrapment and release on a microchip is presented. It is based on the controlled formation of an alginate hydrogel by bringing two laminar flows of alginate and calcium ions in the range of 2 mM to 40 mM into contact. The resulting growth of a gel bar is used to enclose and immobilize yeast cells. Adding ethylenediaminetetraacetic acid (EDTA) to the alginate solution allows for control of the hydrogel growth, and by varying the ratio of Ca(2+) to EDTA concentrations gel growth or gel shrinkage can be induced at will. Trapped cells are released during shrinkage of the gel. The trapping efficiency for different cell speeds is investigated and the properties of gel growth are discussed using a diffusion model. Precise positioning of a single cell is demonstrated. The technique presented allows not only the reversible immobilization of cells under gentle conditions but also offers the potential of long-term cell cultures as shown by on-chip incubation of yeast cells. The procedure may provide a simple and fully biocompatible technique for a multitude of innovative experiments on cells in microsystems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Cited by
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646
Biopolymer-based microgels/nanogels for drug delivery applications
Oh, J. K., Lee, D. I., & Park, J. M. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.08.001 · Cited by 542
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Sahiner, N. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.06.004 · Cited by 333
Metadata
- Authors
- Braschler, T., Johann, R., Heule, M., Metref, L., & Renaud, P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 5
- Pages
- 553
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2026699828
- Cited by
- 97
- References
- 1
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation. https://app.cochat.ai/papers/10.1039/b417604a
- The paper
- Braschler, T., Johann, R., Heule, M., Metref, L., & Renaud, P. (2005). Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation. Lab on a Chip. https://doi.org/10.1039/b417604a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.