Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record.

U–Pb zircon dating by laser ablation-MC-ICP-MS using a new multiple ion counting Faraday collector array

Simonetti, Antonio, Heaman, Larry M., Hartlaub, Russell P., Creaser, Robert A., MacHattie, Trevor G., Böhm, Christian·2005·Journal of Analytical Atomic Spectrometry

Abstract

This study reports U–Pb geochronological data for zircon obtained by laser ablation-multi-collector-ICP-MS using a new collector block design that includes three ion counters and twelve Faraday buckets. The collector configuration allows for simultaneous detection of ion signals from mass 238U to 203Tl, an important factor for the achievement of highly precise and reproducible Pb–Pb and Pb–U ratios. The main advantage of the multiple ion counting system is the capability to readily measure low Pb ion signals (<1 × 106 counts per second) resulting from single spot analyses of ≤40 microns (and corresponding small sample volumes). The latter is an extremely important feature when deciphering multiple domains in complexly zoned zircon populations. A comparative study was conducted between analytical protocols involving non-Tl- and Tl-doped laser ablation runs with regards to evaluating the external reproducibility (i.e., relative standard deviation). The results indicate that the (2σ) external reproducibility for both analytical protocols varies between ∼0.3–1.0% for the 207Pb/206Pb, and ca. 1.3 to <3.0% for the 206Pb/238U (and 207Pb/235U) values. The external reproducibility for the Pb/U values are relatively constant for the Tl-doped analyses, whereas those for the non-Tl runs are inversely correlated with the total absolute (Pb) count rates. The precision and accuracy of both analytical protocols were verified with the analysis of BR266 and 91500 zircon standards and zircons previously dated by ID-TIMS. The instrument configuration and Tl-doping protocol employed here are ideally suited for studies requiring the rapid analysis of a large number (n > 50) of zircon grains.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b504465k

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Simonetti, A., Heaman, L. M., Hartlaub, R. P., Creaser, R. A., MacHattie, T. G., & Böhm, C.
Venue
Journal of Analytical Atomic Spectrometry
Published
2005
Volume
20
Issue
8
Pages
677
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2104949930
Cited by
180
References
0
FWCI
12.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: U–Pb zircon dating by laser ablation-MC-ICP-MS using a new multiple ion counting Faraday collector array. https://app.cochat.ai/papers/10.1039/b504465k
The paper
Simonetti, A., Heaman, L. M., Hartlaub, R. P., Creaser, R. A., MacHattie, T. G., & Böhm, C. (2005). U–Pb zircon dating by laser ablation-MC-ICP-MS using a new multiple ion counting Faraday collector array. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b504465k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.