Abstract

Researchers at UCLA have discovered that the levels of interleukin-8 (IL-8) protein in the saliva of healthy individuals and patients with oropharyngeal squamous cell carcinoma (OSCC) are 30 pM and 86 pM, respectively. In this study, we present the development of the first immunoassay for the quantification of picomolar IL-8 concentrations in human saliva using Biacore surface plasmon resonance (SPR) in a microfluidic channel. A sandwich assay using two monoclonal antibodies, which recognize different epitopes on the antigen (IL-8), was used. Only 13 minutes were required to determine the quantity of pure IL-8 added to just 100 microL of either buffer or saliva-based samples. The limit of detection (LOD) of this immunoassay in buffer was 2.5 pM, and the precision of the response for each concentration was <3% of the coefficient of variation. When first analyzing the saliva supernatants, non-specific binding to the surface was observed. By adding carboxymethyl dextran sodium salt (10 mg mL(-1)) to compete with the surface dextran and primary antibody for non-specific interactions, the signal to noise ratio was greatly improved. The LOD of this immunoassay in saliva was 184 pM. A minimum concentration of 250 pM of exogenous IL-8 could then be consistently detected in a salivary environment. The precision of the response for each IL-8 concentration tested was <7% of the coefficient of variation. Diagnostic sensitivity for oral cancer can be achieved by pre-concentrating the saliva samples 10 fold prior to SPR analysis, making the target levels of IL-8 300 pM for healthy individuals and 860 pM for oral cancer patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b504737d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 165

Metadata

Authors
Yang, C.-Y., Brooks, E., Li, Y., Denny, P., Ho, C.-M., Qi, F., Shi, W., Wolinsky, L., Wu, B., Wong, D. T. W., & Montemagno, C. D.
Venue
Lab on a Chip
Published
2005
Volume
5
Issue
10
Pages
1017
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2165125129
Cited by
165
References
1
FWCI
2.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of picomolar levels of interleukin-8 in human saliva by SPR. https://app.cochat.ai/papers/10.1039/b504737d
The paper
Yang, C.-Y., Brooks, E., Li, Y., Denny, P., Ho, C.-M., Qi, F., Shi, W., Wolinsky, L., Wu, B., Wong, D. T. W., & Montemagno, C. D. (2005). Detection of picomolar levels of interleukin-8 in human saliva by SPR. Lab on a Chip. https://doi.org/10.1039/b504737d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.