New replication technique for the fabrication of thin polymeric microfluidic devices with tunable porosity
Open accessThe DOI matches its Crossref record.
Abstract
In this article we present a new versatile replication method to produce thin polymeric microfluidic devices with tunable porosity. This method is based on phase separation of a polymer solution on a microstructured mold. Compared to existing microfabrication techniques, such as etching and hot embossing, our technique offers four advantages: (a) simple and cheap process that can be performed at room temperature outside clean room facilities; (b) very broad range of applicable materials (including materials that could not be processed before); (c) ability to make thin flexible chips; (d) ability to introduce and tune porosity in the chip. By introducing porosity, the channel walls can be used for selective transport of gasses, liquids and solutes. A proof-of-concept will be given, by showing fast CO2 transport through the channel walls of a porous polymer chip. Furthermore, it will be demonstrated that the gas permeation performance of chips can be enhanced dramatically by a decrease in chip thickness and incorporation of porosity. We expect that the development of porous chips can lead to the on-chip integration of multiple unit operations, such as reaction, separation, gas liquid contacting and membrane emulsification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Membranes and microfluidics: a review
de Jong, J., Lammertink, R. G. H., & Wessling, M. (2006) · Lab on a Chip · doi:10.1039/b603275c · Cited by 483
Self-citationMedical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“[272] J.”
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- de Jong, J., Ankoné, B., Lammertink, R. G. H., & Wessling, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 11
- Pages
- 1240
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2118476148
- Cited by
- 51
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New replication technique for the fabrication of thin polymeric microfluidic devices with tunable porosity. https://app.cochat.ai/papers/10.1039/b509280a
- The paper
- de Jong, J., Ankoné, B., Lammertink, R. G. H., & Wessling, M. (2005). New replication technique for the fabrication of thin polymeric microfluidic devices with tunable porosity. Lab on a Chip. https://doi.org/10.1039/b509280a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.