The DOI matches its Crossref record.
Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars
Abstract
Natural cellular functions are increasingly exploited for integrated chemical systems such as biochemical reactors and biosensors. We propose to utilize the intrinsic mechanical function of cardiomyocytes, converting chemical energy into mechanical energy. In this report, we demonstrate the working principle of our proposed poly(dimethylsiloxane) (PDMS) based cardiomyocyte bio-microactuator using fabricated PDMS micropillars driven to repetitive motion by attached pulsating cardiomyocytes. Sheets of PDMS embedded with an array of micropillars were fabricated and modified for cardiomyocyte attachment in culture. Primary neonatal rat cardiomyocytes were cultured on the array, attaching to the micropillars and substratum successfully, and exhibiting their typical spontaneous, pulsatile phenotype. Micropillars beat with the coupled cells spontaneously without any triggers. The beat frequency was 1.4 Hz at 37 degrees C and the displacement of the top of the pillar that beat most strongly in our observation was 2.8+/-0.2 microm. From this result, contractile forces of cultured cardiomyocytes were estimated to exceed 3.5 microN. The estimated force is far greater than that of a previously described hydrogel-based cardiomyocyte bio-microactuator (K. Morishima et al., in Micro Total Analysis Systems 2003, ed. M. A. Northrup et al., The Transducers Research Foundation, San Diego, CA, vol. 2, pp. 1125-1128). PDMS compatibility as a base material for bio-microactuator design using cultured cardiomyocytes was verified. This PDMS-based cell microactuator worked for about one week without exchange of the culture medium, and this system could be developed for various purposes in the future as self-actuated and efficient mechanochemical transducers without external energy source requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analysis of single mammalian cells on-chip
Sims, C. E., & Allbritton, N. L. (2007) · Lab on a Chip · doi:10.1039/b615235j · Cited by 400
Tissue Engineering Based on Cell Sheet Technology
Matsuda, N., Shimizu, T., Yamato, M., & Okano, T. (2007) · Advanced Materials · doi:10.1002/adma.200701978 · Cited by 398
Self-citationElectrospun conductive nanofibrous scaffolds for engineering cardiac tissue and 3D bioactuators
Wang, L., Wu, Y., Hu, T., Guo, B., & Ma, P. X. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.06.036 · Cited by 318
Denning, C., Borgdorff, V., Crutchley, J., Firth, K. S. A., George, V., Kalra, S., Kondrashov, A., Hoang, M. D., Mosqueira, D., Patel, A., et al. (2016) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2015.10.014 · Cited by 293
Metadata
- Authors
- Tanaka, Y., Morishima, K., Shimizu, T., Kikuchi, A., Yamato, M., Okano, T., & Kitamori, T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 2
- Pages
- 230
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2096827237
- Cited by
- 165
- References
- 0
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars. https://app.cochat.ai/papers/10.1039/b512099c
- The paper
- Tanaka, Y., Morishima, K., Shimizu, T., Kikuchi, A., Yamato, M., Okano, T., & Kitamori, T. (2006). Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars. Lab on a Chip. https://doi.org/10.1039/b512099c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.