The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations
Abstract
This paper presents the characterization of continuous single-stage and three-stage cascade paramagnetic capture (PMC) mode magnetophoretic microseparators for high efficiency separation of red and white blood cells from diluted whole blood based on their native magnetic properties. The separation mechanism for both PMC microseparators is based on a high gradient magnetic separation (HGMS) method. This approach enables separation of blood cells without the use of additives such as magnetic beads. Experimental results for the single-stage PMC microseparator show that 91.1% of red blood cells were continuously separated from the sample at a volumetric flow rate of 5 microl h-1. In addition, the three-stage cascade PMC microseparator continuously separated 93.5% of red blood cells and 97.4% of white blood cells from whole blood at a volumetric flow rate of 5 microl h-1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Red blood cell magnetophoresis
Zborowski, M., Ostera, G. R., Moore, L. R., Milliron, S., Chalmers, J. J., & Schechter, A. N. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75069-3 · Cited by 260
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Metadata
- Authors
- Han, K.-H., & Frazier, A. B.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 2
- Pages
- 265-273
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2074457320
- Cited by
- 205
- References
- 1
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations. https://app.cochat.ai/papers/10.1039/b514539b
- The paper
- Han, K.-H., & Frazier, A. B. (2006). Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations. Lab Chip. https://doi.org/10.1039/b514539b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.