Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A micro-spherical heart pump powered by cultured cardiomyocytes

Tanaka, Yo, Sato, Kae, Shimizu, Tatsuya, Yamato, Masayuki, Okano, Teruo, Kitamori, Takehiko·2007·Lab Chip

Abstract

Miniaturization of chemical or biochemical systems creates extremely efficient devices exploiting the advantages of microspaces. Although they are often targeted for implanted tissue engineered organs or drug-delivery devices because of their highly integrated systems, microfluidic devices are usually powered by external energy sources and therefore difficult to be used in vivo. A microfluidic device powered without the need for external energy sources or stimuli is needed. Previously, we demonstrated the concept of a cardiomyocyte pump using only chemical energy input to cells as a driver (Yo Tanaka, Keisuke Morishima, Tatsuya Shimizu, Akihiko Kikuchi, Masayuki Yamato, Teruo Okano and Takehiko Kitamori, Lab Chip, 6(3), pp. 362-368). However, the structure of this prototype pump described there included complicated mechanical components and fabricated compartments. Here, we have created a micro-spherical heart-like pump powered by spontaneously contracting cardiomyocyte sheets driven without a need for external energy sources or coupled stimuli. This device was fabricated by wrapping a beating cardiomyocyte sheet exhibiting large contractile forces around a fabricated hollow elastomeric sphere (5 mm diameter, 250 microm polymer thickness) fixed with inlet and outlet ports. Fluid oscillations in a capillary connected to the hollow sphere induced by the synchronously pulsating cardiomyocyte sheet were confirmed, and the device continually worked for at least 5 days in this system. This bio/artificial hybrid fluidic pump device is innovative not only because it is driven by cells using only chemical energy input, but also because the design is an optimum structure (sphere). We anticipate that this device might be applied for various purposes including a bio-actuator for medical implant devices that relies on biochemical energy, not electrical interfacing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b612082b

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Tanaka, Y., Sato, K., Shimizu, T., Yamato, M., Okano, T., & Kitamori, T.
Venue
Lab Chip
Published
2007
Volume
7
Issue
2
Pages
207-212
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W1975608706
Cited by
182
References
1
FWCI
7.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.