Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

An inter-laboratory comparison of Si isotope reference materials

Reynolds, Ben C., Aggarwal, Jugdeep, André, Luc, Baxter, Douglas, Beucher, Charlotte, Brzezinski, Mark A., Engström, Emma, Georg, R. Bastian, Land, Magnus, Leng, Melanie J., Opfergelt, Sophie, Rodushkin, Ilia, Sloane, Hilary J., van den Boorn, Sander H. J. M., Vroon, Pieter Z., Cardinal, Damien·2007·J. Anal. At. Spectrom.

Abstract

Three Si isotope materials have been used for an inter-laboratory comparison exercise to ensure reproducibility between international laboratories investigating natural Si isotope variations using a variety of chemical preparation methods and mass spectrometric techniques. These proposed standard reference materials are (i) IRMM-018 (a SiO2 standard), (ii) Big-Batch (a fractionated SiO2 material prepared at the University of California Santa Barbara), and (iii) Diatomite (a natural diatomite sample originally deposited as marine biogenic opal). All analyses are compared with the international Si standard NBS28 (RM8546) and are in reasonable agreement (<±0.22‰ 1σSDδ30Si) given the different measurement techniques involved. These methods include both acid and alkaline dissolution/fusion, Si separation using cation exchange, selective co-precipitation, and gas-source versus plasma-ionization (high and low resolution) mass-spectrometric techniques. The average δ30Si for Diatomite, IRMM-018, and Big-Batch are +1.26‰, −1.65‰ and −10.48‰, respectively, with corresponding δ29Si values of +0.64‰, −0.85‰ and −5.35‰ for the same standards, respectively. For the most fractionated standard (Big-Batch), results demonstrate a kinetic mass-dependent fractionation effect for atomic Si (i.e., δ29Si ∼ 0.51 × δ30Si). There is almost no statistical difference between the mean values obtained by each participating laboratory, with the notable exception of the IRMM-018 standard. This effect could be caused by heterogeneity or contamination of this standard. The results for the other two standards indicate that data sets produced using any of the methods employed in this study will have similar precision and differences are limited to 0.2‰ in mean δ30Si values for a given sample between laboratories, or differences of 0.13‰ in mean δ29Si values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b616755a

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 279

Metadata

Authors
Reynolds, B. C., Aggarwal, J., André, L., Baxter, D., Beucher, C., Brzezinski, M. A., Engström, E., Georg, R. B., Land, M., Leng, M. J., Opfergelt, S., Rodushkin, I., Sloane, H. J., van den Boorn, S. H. J. M., Vroon, P. Z., & Cardinal, D.
Venue
J. Anal. At. Spectrom.
Published
2007
Volume
22
Issue
5
Pages
561-568
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2081993348
Cited by
279
References
33
FWCI
14.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An inter-laboratory comparison of Si isotope reference materials. https://app.cochat.ai/papers/10.1039/b616755a
The paper
Reynolds, B. C., Aggarwal, J., André, L., Baxter, D., Beucher, C., Brzezinski, M. A., Engström, E., Georg, R. B., Land, M., Leng, M. J., Opfergelt, S., Rodushkin, I., Sloane, H. J., van den Boorn, S. H. J. M., Vroon, P. Z., & Cardinal, D. (2007). An inter-laboratory comparison of Si isotope reference materials. J. Anal. At. Spectrom. https://doi.org/10.1039/b616755a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.