The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Artificial cilia for active micro-fluidic mixing
Abstract
In lab-on-chip devices, on which complete (bio-)chemical analysis laboratories are miniaturized and integrated, it is essential to manipulate fluids in sub-millimetre channels and sub-microlitre chambers. A special challenge in these small micro-fluidic systems is to create good mixing flows, since it is almost impossible to generate turbulence. We propose an active micro-fluidic mixing concept inspired by nature, namely by micro-organisms that swim through a liquid by oscillating microscopic hairs, cilia, that cover their surface. We have fabricated artificial cilia consisting of electro-statically actuated polymer structures, and have integrated these in a micro-fluidic channel. Flow visualization experiments show that the cilia can generate substantial fluid velocities, up to 0.6 mm s(-1). In addition, very efficient mixing is obtained using specially designed geometrical cilia configurations in a micro-channel. Since the artificial cilia can be actively controlled using electrical signals, they have exciting applications in micro-fluidic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
A revolution in optical manipulation
Grier, D. G. (2003) · Nature · doi:10.1038/nature01935 · Cited by 5,123
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Aref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Microscopic artificial swimmers
Dreyfus, R., Baudry, J., Roper, M. L., Fermigier, M., Stone, H. A., & Bibette, J. (2005) · Nature · doi:10.1038/nature04090 · Cited by 1,853
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Analysis of the swimming of microscopic organisms
Taylor, G. I. (1951) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1951.0218 · Cited by 1,066
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Controlled vesicle deformation and lysis by single oscillating bubbles
Marmottant, P., & Hilgenfeldt, S. (2003) · Nature · doi:10.1038/nature01613 · Cited by 853
A magnetic microstirrer and array for microfluidic mixing
Lu, L.-H., Ryu, K. S., & Liu, C. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.802899 · Cited by 446
Moving Fluid with Bacterial Carpets
Darnton, N., Turner, L., Breuer, K., & Berg, H. C. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74253-8 · Cited by 376
Enhancement of microfluidic mixing using time pulsing
Glasgow, I., & Aubry, N. (2003) · Lab Chip · doi:10.1039/b302569a · Cited by 370
Magnetically Actuated Nanorod Arrays as Biomimetic Cilia
Evans, E. E., Shields, A. R., Carroll, R. L., Washburn, S., Falvo, M. R., & Superfine, R. (2007) · Nano Letters · doi:10.1021/nl070190c · Cited by 304
Ottino, J. M. (1989) · Cited by 151
Frequency and directional responses of cilia to membrane potential changes inParamecium
Machemer, H. (1974) · Journal of Comparative Physiology A · doi:10.1007/bf00696617 · Cited by 140
Sleigh, M. A. (1974) · Medical Entomology and Zoology · Cited by 87
Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography
Xi, C., Marks, D. L., Parikh, D. S., Raskin, L. M., & Boppart, S. A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402433101 · Cited by 64
Cited by
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Printed artificial cilia from liquid-crystal network actuators modularly driven by light
van Oosten, C. L., Bastiaansen, C. W. M., & Broer, D. J. (2009) · Nature Materials · doi:10.1038/nmat2487 · Cited by 971
Self-citationBiomaterial systems for mechanosensing and actuation
Fratzl, P., & Barth, F. G. (2009) · Nature · doi:10.1038/nature08603 · Cited by 706
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Magnetic cilia carpets with programmable metachronal waves
Gu, H., Boehler, Q., Cui, H., Secchi, E., Savorana, G., De Marco, C., Gervasoni, S., Peyron, Q., Huang, T.-Y., Pane, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16458-4 · Cited by 329
Metadata
- Authors
- Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., Khatavkar, V., & Anderson, P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 4
- Pages
- 533
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2138202986
- Cited by
- 296
- References
- 22
- FWCI
- 13.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.