The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cell research with physically modified microfluidic channels: A review
Abstract
An overview of the use of physically modified microfluidic channels towards cell research is presented. The physical modification can be realized either by combining embedded physical micro/nanostructures or a topographically patterned substrate at the micro- or nanoscale inside a channel. After a brief description of the background and the importance of the physically modified microfluidic system, various fabrication methods are described based on the materials and geometries of physical structures and channels. Of many operational principles for microfluidics (electrical, magnetic, optical, mechanical, and so on), this review primarily focuses on mechanical operation principles aided by structural modification of the channels. The mechanical forces are classified into (i) hydrodynamic, (ii) gravitational, (iii) capillary, (iv) wetting, and (v) adhesion forces. Throughout this review, we will specify examples where necessary and provide trends and future directions in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wettability of porous surfaces
Cassie, A. B. D., & Baxter, S. (1944) · Transactions of the Faraday Society · doi:10.1039/tf9444000546 · Cited by 13,807
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Cited by
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Self-citationA Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
3D Bioprinting of Tissue/Organ Models
Pati, F., Gantelius, J., & Svahn, H. A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505062 · Cited by 301
Study on Invadopodia Formation for Lung Carcinoma Invasion with a Microfluidic 3D Culture Device
Wang, S., Li, E., Gao, Y., Wang, Y., Guo, Z., He, J., Zhang, J., Gao, Z., & Wang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056448 · Cited by 65
Metadata
- Authors
- Kim, S. M., Lee, S. H., & Suh, K. Y.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 7
- Pages
- 1015
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2104073671
- Cited by
- 166
- References
- 2
- FWCI
- 10.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.