The DOI matches its Crossref record.
Efficient blue-emitting silafluorene–fluorene-conjugated copolymers: selective turn-off/turn-on detection of explosives
Abstract
The synthesis and spectroscopic characterization of a series of new blue-emitting silafluorene–fluorene copolymers is described. The polymers are synthesized using kinetically controlled hydrosilylation copolymerization of 1,1-dihydridosilafluorene with a series of 9-substituted 2,7-diethynylfluorenes. The polymers contain a trans-only framework with molecular weights in the range of 13 000–20 000, as determined by gel permeation chromatography (GPC) using polystyrene standards, and by 1H NMR spectroscopy using dimethylphenylsilane as an end-capping marker group. The three stereoregular polymers synthesized include a 9,9-dihydridofluorene (PSF1), a 9,9-dimethyl-9H-fluorene (PSF2), and a 9,9′-spirobifluorene (PSF3) comonomer with the frameworks. These fluorenyl units are conjugated through the silicon center of the silafluorene moiety by bridging vinylene groups. Quantum yields of fluorescence range from 20 to 100% with PSF3 having the highest quantum efficiency. Polymers PSF1-3 emit in the blue region of the spectrum (∼475 nm), showing good color purity with little change in luminescence properties between the solution and solid-state phases. The polymers were tested for explosives detection properties by a fluorescence-quenching mechanism. Targeted explosives include laboratory prepared TNT, DNT, picric acid, RDX, HMX, PETN, TNG, and Tetryl, as well as production line PETN and C-4. All three polymers exhibit detection of explosive particulates with limits as low as 1 pg cm−2 for Tetryl. Polymer PSF1 simultaneously acts as a selective fluorescence “turn-on” sensor for nitrate ester explosives when irradiated with UV light. In the presence of nitrate ester-based explosives such as PETN, PSF1 initially exhibits fluorescence quenching, but continued exposure to UV-light (302 nm), promotes a photochemical reaction forming a luminescent green fluorenone copolymer. This is the first example of a single material acting as both a turn-off and turn-on selective fluorescent sensor for an explosive material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Optical chemosensors and reagents to detect explosives
Salinas, Y., Martínez-Máñez, R., Marcos, M. D., Sancenón, F., Costero, A. M., Parra, M., & Gil, S. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15173h · Cited by 1,144
Metadata
- Authors
- Sanchez, J. C., & Trogler, W. C.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 18
- Issue
- 26
- Pages
- 3143
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2005025295
- Cited by
- 211
- References
- 0
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient blue-emitting silafluorene–fluorene-conjugated copolymers: selective turn-off/turn-on detection of explosives. https://app.cochat.ai/papers/10.1039/b802623h
- The paper
- Sanchez, J. C., & Trogler, W. C. (2008). Efficient blue-emitting silafluorene–fluorene-conjugated copolymers: selective turn-off/turn-on detection of explosives. Journal of Materials Chemistry. https://doi.org/10.1039/b802623h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.