The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Viscoelastic, mechanical, and dielectric measurements on complex samples with the quartz crystal microbalance
Abstract
Piezoelectric resonators have been in use as mass-sensing devices for almost half a century. More recently it was recognized that shifts in frequency and bandwidth can come about by a diverse variety of interactions with the sample. The classical "load" consists of a thin film, which shifts the resonance frequency due to its inertia. Other types of loading include semi-infinite viscoelastic media, rough objects contacting the crystal via isolated asperities, mechanically nonlinear contacts, and dielectric films. All these interactions can be analyzed within the small-load approximation. The small-load approximation provides a unified frame for interpretation and thereby opens the way to new applications of the QCM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Surface energy and the contact of elastic solids
Johnson, K. L., Kendall, K., & Roberts, A. D. (1971) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1971.0141 · Cited by 8,061
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
(1998) · doi:10.1142/3481 · Cited by 4,436
Elastic Spheres in Contact Under Varying Oblique Forces
Mindlin, R. D., & Deresiewicz, H. (1953) · Journal of Applied Mechanics · doi:10.1115/1.4010702 · Cited by 2,782
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Direct measurement of colloidal forces using an atomic force microscope
Ducker, W. A., Senden, T. J., & Pashley, R. M. (1991) · Nature · doi:10.1038/353239a0 · Cited by 2,075
Laibinis, P. E., Whitesides, G. M., Allara, D. L., Tao, Y. T., Parikh, A. N., & Nuzzo, R. G. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00019a011 · Cited by 1,974
Cited by
Reviakine, I., Johannsmann, D., & Richter, R. P. (2011) · Analytical Chemistry · doi:10.1021/ac201778h · Cited by 871
Self-citationLevi, M. D., Lukatskaya, M. R., Sigalov, S., Beidaghi, M., Shpigel, N., Daikhin, L., Aurbach, D., Barsoum, M. W., & Gogotsi, Y. (2015) · Advanced Energy Materials · doi:10.1002/aenm.201400815 · Cited by 384
Metadata
- Authors
- Johannsmann, D.
- Venue
- Physical Chemistry Chemical Physics
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 10
- Issue
- 31
- Pages
- 4516
- ISSN
- 1463-9076 (ISSN-L)
- 1463-9084
- OpenAlex
- W1967862079
- Cited by
- 297
- References
- 44
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.