Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 379

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Initial performance metrics of a new custom-designed ArF excimer LA-ICPMS system coupled to a two-volume laser-ablation cell

Müller, Wolfgang, Shelley, Michael, Miller, Pascal, Broude, Sergey·2009·J. Anal. At. Spectrom.

Abstract

A new custom-built excimer (193 nm) laser-ablation system with two-volume laser-ablation cell coupled to a quadrupole ICPMS is described, which combines rapid (<1.5 s for 99%) signal washout with full flexibility in sample size (50 × 50 × 25 mm) and high sensitivity (>10000 cps/ppm for mid-high m/z, 55 μm, 5 Hz). An application of reconstructing medieval Pb exposure highlights the need for rapid signal washout in unravelling strongly varying Pb peaks in well-preserved archaeological tooth enamel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b805995k

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 379

Metadata

Authors
Müller, W., Shelley, M., Miller, P., & Broude, S.
Venue
J. Anal. At. Spectrom.
Published
2009
Volume
24
Issue
2
Pages
209-214
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W1978862323
Cited by
379
References
10
FWCI
11.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Initial performance metrics of a new custom-designed ArF excimer LA-ICPMS system coupled to a two-volume laser-ablation cell. https://app.cochat.ai/papers/10.1039/b805995k
The paper
Müller, W., Shelley, M., Miller, P., & Broude, S. (2009). Initial performance metrics of a new custom-designed ArF excimer LA-ICPMS system coupled to a two-volume laser-ablation cell. J. Anal. At. Spectrom. https://doi.org/10.1039/b805995k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.