The DOI matches its Crossref record.
The deformation of flexible PDMS microchannels under a pressure driven flow
Abstract
Poly(dimethylsiloxane) (PDMS) microchannels are commonly used microfluidic structures that have a wide variety of biological testing applications, including the simulation of blood vessels to study the mechanics of vascular disease. In these studies in particular, the deformation of the channel due to the pressure inside is a critical parameter. We describe a method for using fluorescence microscopy to quantify the deformation of such channels under pressure driven flow. Additionally, the relationship between wall thickness and channel deformation is investigated. PDMS microchannels of varying top wall thickness were created using a soft lithography process. A solution of fluorescent dye is pumped through the channels at constant volume flow rates and illuminated. Pressure and fluorescence intensity are measured at five positions along the length of the channel. Fluorescence measurements are then used to determine deformation, using the linear relationship of dye layer thickness and intensity. A linear relationship between pressure and microchannel deformation is measured. Pressure drops and deformations closely correspond to values predicted by the model in most cases. Additionally, measured pressure drops are found to be up to 35% less than the pressure drop in a rigid-walled channel, and channel wall thickness is found to have an increasing effect as the channel wall thickness decreases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rapid prototyping polymers for microfluidic devices and high pressure injections
Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20514e · Cited by 407
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Metadata
- Authors
- Hardy, B. S., Uechi, K., Zhen, J., & Pirouz Kavehpour, H.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 7
- Pages
- 935-938
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1974040144
- Cited by
- 203
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The deformation of flexible PDMS microchannels under a pressure driven flow. https://app.cochat.ai/papers/10.1039/b813061b
- The paper
- Hardy, B. S., Uechi, K., Zhen, J., & Pirouz Kavehpour, H. (2009). The deformation of flexible PDMS microchannels under a pressure driven flow. Lab Chip. https://doi.org/10.1039/b813061b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.