CoChat

Plastic–PDMS bonding for high pressure hydrolytically stable active microfluidics

Lee, Kevin S., Ram, Rajeev J. · 2009 · Lab on a Chip
Cited by 141

The DOI matches its Crossref record.

Abstract

We explore the application of organofunctional silanes for bonding plastic substrates to PDMS membranes. Such devices would enable actuated membrane microfluidics in plastic devices. Bond strength degradation in aqueous environments can be reduced by using bis-silanes with larger alkoxy end groups to promote organofunctional bond formation with the plastic substrate. Hydrolytic failure can also result from low silane crosslink density or interface hydrophilicity. A test device consisting of three-valve peristaltic pumps is fabricated out of polycarbonate (PC) and bonded to PDMS through isopropoxy modified bis-trimethoxy-silyl-propyl-amine. Valves operated up to 60 psi in aqueous environments without failure. Solutions of DI water and 1 M HCl were also pumped through the device via peristaltic actuation at 18 psi for 2 weeks without bond failure. 1 M NaOH was also tested but resulted in bond failure after 115 hours.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b820924c

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Lee, K. S., & Ram, R. J.
Venue
Lab on a Chip
Published
2009
Volume
9
Issue
11
Pages
1618
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2089350615
Cited by
141
References
0
FWCI
4.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plastic–PDMS bonding for high pressure hydrolytically stable active microfluidics. https://app.cochat.ai/papers/10.1039/b820924c
The paper
Lee, K. S., & Ram, R. J. (2009). Plastic–PDMS bonding for high pressure hydrolytically stable active microfluidics. Lab on a Chip. https://doi.org/10.1039/b820924c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.