The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Nanofluidic concentration devices for biomolecules utilizing ion concentration polarization: theory, fabrication, and applications
Open accessAbstract
Recently, a new type of electrokinetic concentration devices has been developed in a microfluidic chip format, which allows efficient trapping and concentration of biomolecules by utilizing ion concentration polarization near nanofluidic structures. These devices have drawn much attention not only due to their potential application in biomolecule sensing, but also due to the rich scientific content related to ion concentration polarization, the underlying physical phenomenon for the operation of these electrokinetic concentration devices. This tutorial review provides an introduction to the scientific and engineering advances achieved, in-depth discussion about several interesting applications of these unique concentration devices, and their current limitations and challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Physicochemical hydrodynamics: an introduction
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3319 · Cited by 878
Nested self-similar wrinkling patterns in skins
Efimenko, K., Rackaitis, M., Manias, E., Vaziri, A., Mahadevan, L., & Genzer, J. (2005) · Nature Materials · doi:10.1038/nmat1342 · Cited by 774
Million-fold Preconcentration of Proteins and Peptides by Nanofluidic Filter
Wang, Y.-C., Stevens, A. L., & Han, J. (2005) · Analytical Chemistry · doi:10.1021/ac050321z · Cited by 618
Self-citationElectro-osmotically induced convection at a permselective membrane
Rubinstein, I., & Zaltzman, B. (2000) · Physical Review E · doi:10.1103/physreve.62.2238 · Cited by 615
Concentration Polarization and Nonlinear Electrokinetic Flow near a Nanofluidic Channel
Kim, S. J., Wang, Y.-C., Lee, J. H., Jang, H., & Han, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.044501 · Cited by 555
Self-citationIon-Enrichment and Ion-Depletion Effect of Nanochannel Structures
Pu, Q., Yun, J., Temkin, H., & Liu, S. (2004) · Nano Letters · doi:10.1021/nl0494811 · Cited by 532
Ion Transport in Nanofluidic Channels
Daiguji, H., Yang, P., & Majumdar, A. (2004) · Nano Letters · doi:10.1021/nl0348185 · Cited by 520
Electro-osmotic slip and electroconvective instability
ZALTZMAN, B., & RUBINSTEIN, I. (2007) · Journal of Fluid Mechanics · doi:10.1017/s0022112007004880 · Cited by 416
Cited by
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Desalination at overlimiting currents: State-of-the-art and perspectives
Nikonenko, V. V., Kovalenko, A. V., Urtenov, M. K., Pismenskaya, N. D., Han, J., Sistat, P., & Pourcelly, G. (2014) · Desalination · doi:10.1016/j.desal.2014.01.008 · Cited by 405
Self-citation
Metadata
- Authors
- Kim, S. J., Song, Y.-A., & Han, J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 3
- Pages
- 912
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2171958864
- Cited by
- 405
- References
- 18
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanofluidic concentration devices for biomolecules utilizing ion concentration polarization: theory, fabrication, and applications. https://app.cochat.ai/papers/10.1039/b822556g
- The paper
- Kim, S. J., Song, Y.-A., & Han, J. (2010). Nanofluidic concentration devices for biomolecules utilizing ion concentration polarization: theory, fabrication, and applications. Chemical Society Reviews. https://doi.org/10.1039/b822556g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.