The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme
Abstract
Microdroplets in water-in-oil emulsions can be used as microreactors with volumes 10(3) to 10(9) times smaller than the smallest working volumes in a microtitre plate well (1-2 microL). However, many reactions and assays require multiple steps where new reagents are added at defined times, to start, modify or terminate a reaction. The most flexible way to add new reagents to pre-formed droplets is by controlled, pairwise droplet fusion. We describe a droplet-based microfluidic system capable of performing multiple operations, including pairwise droplet fusion, to analyze complex and sequential multi-step reactions. It is exemplified by performing a series of six on-chip and two off-chip operations which enable the coupled in vitro transcription and translation of cotA laccase genes in droplets and, after performing a controlled fusion with droplets containing laccase assay reagents, the end-point and kinetic analysis of the catalytic activity of the translated protein. In vitro translation and the laccase assay must be performed sequentially as the conditions for the laccase assay are not compatible with in vitro translation. Droplet fusion was performed by electrocoalescence at a rate of approximately 3000 fusion events per second and nearly 90% of droplets were fused one-to-one (one droplet containing in vitro translated laccase fused to one droplet containing the reagents for the laccase assay). The ability to uncouple the enzymatic assay from in vitro translation greatly extends the range of activities of in vitro translated proteins that can potentially be screened in droplet-based microfluidic systems. Furthermore, the system also opens up the possibility of performing a wide range of other new (bio)chemical reactions in droplets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Cited by
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Self-citationDroplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Transient compartmentalization of RNA replicators prevents extinction due to parasites
Matsumura, S., Kun, Á., Ryckelynck, M., Coldren, F., Szilágyi, A., Jossinet, F., Rick, C., Nghe, P., Szathmáry, E., & Griffiths, A. D. (2016) · Science · doi:10.1126/science.aag1582 · Cited by 162
Self-citation
Metadata
- Authors
- Mazutis, L., Baret, J.-C., Treacy, P., Skhiri, Y., Araghi, A. F., Ryckelynck, M., Taly, V., & Griffiths, A. D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 20
- Pages
- 2902
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2025915013
- Cited by
- 205
- References
- 1
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme. https://app.cochat.ai/papers/10.1039/b907753g
- The paper
- Mazutis, L., Baret, J.-C., Treacy, P., Skhiri, Y., Araghi, A. F., Ryckelynck, M., Taly, V., & Griffiths, A. D. (2009). Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme. Lab on a Chip. https://doi.org/10.1039/b907753g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.