The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A multiplexed optofluidic biomolecular sensor for low mass detection
Open accessAbstract
Optical techniques have proven to be well suited for in situ biomolecular sensing because they enable high fidelity measurements in aqueous environments, are minimally affected by background solution pH or ionic strength, and facilitate label-free detection. Recently, there has been significant interest in developing new classes of optically resonant biosensors possessing very high quality-factors. This high quality-factor enables them to resolve the presence of very small amounts of bound mass and leads to very low limits of detection. A drawback of these devices is that the majority of the resonant electromagnetic energy is confined within the solid light-guiding structure thus limiting the degree to which it overlaps with the bound matter. This in turn lowers the ultimate device sensitivity, or the change in output signal in response to changes in bound mass. Here we present a novel optofluidic biosensor platform that incorporates a unique one-dimensional photonic crystal resonator array which enables significantly stronger light-matter interaction. We show here how this, coupled with the ability of planar photonic crystals to spatially localize the optical field to mode volumes on the order of a wavelength cubed, enables a limit of detection on the order of 63 ag total bound mass (estimated using a polyelectrolyte growth model) and a device sensitivity an order of magnitude better than similar devices. The multiplexing capabilities of our sensor are demonstrated by the individual and concurrent detection of interleukins 4, 6 and 8 using a sandwich assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
On-chip gas detection in silicon optical microcavities
Robinson, J. T., Chen, L., & Lipson, M. (2008) · Optics Express · doi:10.1364/oe.16.004296 · Cited by 342
Cited by
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
High-Q Optical Sensors for Chemical and Biological Analysis
Luchansky, M. S., & Bailey, R. C. (2012) · Analytical Chemistry · doi:10.1021/ac2029024 · Cited by 288
Optofluidics for energy applications
Erickson, D., Sinton, D., & Psaltis, D. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.209 · Cited by 277
Self-citation
Metadata
- Authors
- Mandal, S., Goddard, J. M., & Erickson, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 20
- Pages
- 2924
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2127524981
- Cited by
- 159
- References
- 2
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multiplexed optofluidic biomolecular sensor for low mass detection. https://app.cochat.ai/papers/10.1039/b907826f
- The paper
- Mandal, S., Goddard, J. M., & Erickson, D. (2009). A multiplexed optofluidic biomolecular sensor for low mass detection. Lab on a Chip. https://doi.org/10.1039/b907826f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.