The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Patterning of superhydrophobic paper to control the mobility of micro-liter drops for two-dimensional lab-on-paper applications
Abstract
Superhydrophobic paper substrates were patterned with high surface energy black ink using commercially available desktop printing technology. The shape and size of the ink islands were designed to control the adhesion forces on water drops in two directions, parallel ('drag-adhesion') and perpendicular ('extensional-adhesion') to the substrate. Experimental data on the adhesion forces shows good agreement with classical models for 'drag' (Furmidge equation) and 'extensional' adhesion (modified Dupré equation). The tunability of the two adhesion forces was used to implement four basic unit operations for the manipulation of liquid drops on the paper substrates: storage, transfer, mixing and sampling. By combining these basic functionalities it is possible to design simple two-dimensional lab-on-paper (LOP) devices. In our 2D LOP prototype, liquid droplets adhere to the porous substrate, rather than absorbing into the paper; as a result, liquid droplets remain accessible for further quantitative testing and analysis, after performing simple qualitative on-chip testing. In addition, the use of commercially available desktop printers and word processing software to generate ink patterns enable end users to design LOP devices for specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Ghosh, A., Ganguly, R., Schutzius, T. M., & Megaridis, C. M. (2014) · Lab Chip · doi:10.1039/c3lc51406d · Cited by 379
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Recent Advances in TiO2‐Based Nanostructured Surfaces with Controllable Wettability and Adhesion
Lai, Y., Huang, J., Cui, Z., Ge, M., Zhang, K., Chen, Z., & Chi, L. (2016) · Small · doi:10.1002/smll.201501837 · Cited by 329
Li, J., Rossignol, F., & Macdonald, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00235d · Cited by 307
Superhydrophobic Coatings on Cellulose‐Based Materials: Fabrication, Properties, and Applications
Teisala, H., Tuominen, M., & Kuusipalo, J. (2014) · Advanced Materials Interfaces · doi:10.1002/admi.201300026 · Cited by 270
Metadata
- Authors
- Balu, B., Berry, A. D., Hess, D. W., & Breedveld, V.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 21
- Pages
- 3066
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2171579962
- Cited by
- 174
- References
- 1
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patterning of superhydrophobic paper to control the mobility of micro-liter drops for two-dimensional lab-on-paper applications. https://app.cochat.ai/papers/10.1039/b909868b
- The paper
- Balu, B., Berry, A. D., Hess, D. W., & Breedveld, V. (2009). Patterning of superhydrophobic paper to control the mobility of micro-liter drops for two-dimensional lab-on-paper applications. Lab on a Chip. https://doi.org/10.1039/b909868b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.