The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Nanofluidic technology for biomolecule applications: a critical review
Abstract
In this review, we present nanofluidic phenomena, particularly as they relate to applications involving analysis of biomolecules within nanofabricated devices. The relevant length scales and physical phenomena that govern biomolecule transport and manipulation within nanofabricated nanofluidic devices are reviewed, the advantages of nanofabricated devices are presented, and relevant applications are cited. Characteristic length scales include the Debye length, the Van der Waals radius, the action distance of hydrogen bonding, the slip length, and macromolecular dimensions. On the basis of the characteristic lengths and related nanofluidic phenomena, a nanofluidic toolbox will be assembled. Nanofluidic phenomena that affect biomolecule behavior within such devices can include ion depletion and enrichment, modified velocity and mobility, permselectivity, steric hindrance, entropy, adsorption, and hydrodynamic interaction. The complex interactions and coupled physics of such phenomena allow for many applications, including biomolecule separation, concentration, reaction/hybridization, sequencing (in the case of DNA) and detection. Examples of devices for such applications will be presented, followed by a discussion of near-term challenges and future thoughts for the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Dynamic instability of microtubule growth
Mitchison, T., & Kirschner, M. (1984) · Nature · doi:10.1038/312237a0 · Cited by 3,337
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Nanoporous anodic aluminium oxide: Advances in surface engineering and emerging applications
Md Jani, A. M., Losic, D., & Voelcker, N. H. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.01.002 · Cited by 553
Stochastic Eulerian Lagrangian methods for fluid–structure interactions with thermal fluctuations
Atzberger, P. J. (2011) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.12.028 · Cited by 94
The immersed molecular finite element method
Kopacz, A. M., Patankar, N. A., & Liu, W. K. (2012) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2012.04.005 · Cited by 16
Metadata
- Authors
- Napoli, M., Eijkel, J. C. T., & Pennathur, S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 8
- Pages
- 957
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2137779706
- Cited by
- 237
- References
- 3
- FWCI
- 14.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanofluidic technology for biomolecule applications: a critical review. https://app.cochat.ai/papers/10.1039/b917759k
- The paper
- Napoli, M., Eijkel, J. C. T., & Pennathur, S. (2010). Nanofluidic technology for biomolecule applications: a critical review. Lab on a Chip. https://doi.org/10.1039/b917759k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.