The DOI matches its Crossref record.
Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas
Abstract
Ambient ionization mass spectrometry allows the rapid analysis of samples or objects in their native state in the open environment with no prior preparation. Over the past six years, the ability of these techniques to provide selective analyte desorption and ionization, in combination with mass spectrometry (MS), has provided a growing number of powerful analytical alternatives across broad application areas, both quantitative and qualitative in nature, including pharmaceutical analysis, process chemistry, biological imaging, in vivo analysis, proteomics, metabolomics, forensics, and explosives detection. With the emergence of new ambient ionization methods, and the complementary nature of existing desorption and/or ionization techniques, additional hyphenated methods have been devised, which pushes the total number of documented methods to almost thirty. To cover all current ambient ionization techniques in detail would be too complex and detract from the main objective of this review. Rather, an overview of the field of ambient ionization MS will be given, followed by broad classification to allow detailed discussion of theory and common mechanistic factors underpinning a number of key techniques. Consideration will be given to experimental design, ease of implementation and analytical performance, detailing subsequent impact on a number of application areas, both established and emerging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Metadata
- Authors
- Weston, D. J.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 4
- Pages
- 661
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2076481451
- Cited by
- 357
- References
- 0
- FWCI
- 23.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas. https://app.cochat.ai/papers/10.1039/b925579f
- The paper
- Weston, D. J. (2010). Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas. The Analyst. https://doi.org/10.1039/b925579f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.