Cited by 171Innovative Microfluidic and Catalytic Techniques InnovationAdvanced Drug Delivery SystemsMicrofluidic and Capillary Electrophoresis Applications

PLGA micro/nanosphere synthesis by droplet microfluidic solvent evaporation and extraction approaches

Hung, Lung-Hsin, Teh, Shia-Yen, Jester, James, Lee, Abraham P.·2010·Lab on a Chip

Abstract

In this paper, we present two approaches for the synthesis of poly(lactide-co-glycolide) (PLGA) micro/nanospheres using non-toxic organic solvents in droplet-based microfluidic platforms. Solvent evaporation and solvent extraction methods were employed to enable the controlled generation of monodisperse PLGA particles that range from 70 nanometres to 30 microns in diameter. Determination of particle size was carried out with dynamic light scattering (DLS) and image analysis to show less than 2% variation in particle size. Sizes of the PLGA microspheres were controlled by the PLGA concentration in solvent and by the relative flow rates of oil and aqueous phases in the system. A penetration imaging assay was performed to determine the depth of diffusion of a model drug molecule fluorescein, out of the PLGA nanoparticles into corneal tissue. With the ability to prepare high quality, monodisperse, biodegradable particles, our methods have great potential to benefit drug delivery applications.

Integrity signals

Registry

Crossref · 10.1039/c002866e

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Several new methods for manufacturing PLGA or PLA particles have been reported, including ultrasonic atomization, electrospray, microfluidic, pore-closing/thermoreversible-gel, and microfabrication.

    “Recently, several new methods to manufacture PLGA or PLA particles have been reported, such as the ultrasonic atomization method [14,15], the electrospray method [16], the microfluidic method [17,18], the pore-closing and thermoreversible-gel method [19,20], and the microfabrication method [21].”

The citation lists haven’t been fetched yet

References 35 · Cited by 171

Authors
Hung, L.-H., Teh, S.-Y., Jester, J., & Lee, A. P.
Affiliations
University of California, Irvine (US)
Corresponding author
Lee, Abraham P.
Venue
Lab on a Chip
Published
2010
Volume
10
Issue
14
Pages
1820
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2132347923
Cited by
171
References
35
Citations by year
2026: 9 · 2025: 10 · 2024: 6 · 2023: 7 · 2022: 9 · 2021: 13 · 2020: 5 · 2019: 17 · 2018: 8 · 2017: 17 · 2016: 15 · 2015: 13 · 2014: 12 · 2013: 11 · 2012: 10
FWCI
5.46
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Innovative Microfluidic and Catalytic Techniques Innovation
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
PLGA, poly(lactic-co-glycolic acid), droplet microfluidics, solvent evaporation, solvent extraction, monodisperse particles, particle size control, corneal tissue, biodegradable nanoparticles, drug delivery
MeSH terms
Polylactic Acid-Polyglycolic Acid Copolymer, Gases, Microspheres, Polyglycolic Acid, Solvents, Lactic Acid, Nanotechnology, Microfluidic Analytical Techniques, Solid Phase Extraction, Nanospheres

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review