Microfluidic perfusion system for maintaining viable heart tissue with real-time electrochemical monitoring of reactive oxygen species
Open accessThe DOI matches its Crossref record.
Abstract
A microfluidic device has been developed to maintain viable heart tissue samples in a biomimetic microenvironment. This device allows rat or human heart tissue to be studied under pseudo in vivo conditions. Effluent levels of lactate dehydrogenase and hydrogen peroxide were used as markers of damaged tissue in combination with in situ electrochemical measurement of the release of reactive oxygen species (ROS). The parameters for perfusion were optimized to maintain biopsies of rat right ventricular or human right atrial tissue viable for up to 5 and 3.5 hours, respectively. Electrochemical assessment of the oxidation current of total ROS, employing cyclic voltammetry, gave results in real-time that were in good agreement to biochemical assessment using conventional, off-chip, commercial assays. This proof-of-principle, integrated microfluidic device, may be exploited in providing a platform technology for future cardiac research, offering an alternative approach for investigating heart pathophysiology and facilitating the development of new therapeutic strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Micro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Three Dimensional Microfluidic Cell Arrays for ex Vivo Drug Screening with Mimicked Vascular Flow
Dereli-Korkut, Z., Akaydin, H. D., Ahmed, A. H. R., Jiang, X., & Wang, S. (2014) · Analytical Chemistry · doi:10.1021/ac403899j · Cited by 62
Metadata
- Authors
- Cheah, L.-T., Dou, Y.-H., Seymour, A.-M. L., Dyer, C. E., Haswell, S. J., Wadhawan, J. D., & Greenman, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 20
- Pages
- 2720
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2048315123
- Cited by
- 57
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic perfusion system for maintaining viable heart tissue with real-time electrochemical monitoring of reactive oxygen species. https://app.cochat.ai/papers/10.1039/c004910g
- The paper
- Cheah, L.-T., Dou, Y.-H., Seymour, A.-M. L., Dyer, C. E., Haswell, S. J., Wadhawan, J. D., & Greenman, J. (2010). Microfluidic perfusion system for maintaining viable heart tissue with real-time electrochemical monitoring of reactive oxygen species. Lab on a Chip. https://doi.org/10.1039/c004910g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.