The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hard and soft X-ray microscopy and tomography in catalysis: bridging the different time and length scales
Abstract
X-ray microscopic techniques are excellent and presently emerging techniques for chemical imaging of heterogeneous catalysts. Spatially resolved studies in heterogeneous catalysis require the understanding of both the macro and the microstructure, since both have decisive influence on the final performance of the industrially applied catalysts. A particularly important aspect is the study of the catalysts during their preparation, activation and under operating conditions, where X-rays have an inherent advantage due to their good penetration length especially in the hard X-ray regime. Whereas reaction cell design for hard X-rays is straightforward, recently smart in situ cells have also been reported for the soft X-ray regime. In the first part of the tutorial review, the constraints from a catalysis view are outlined, then the scanning and full-field X-ray microscopy as well as coherent X-ray diffraction imaging techniques are described together with the challenging design of suitable environmental cells. Selected examples demonstrate the application of X-ray microscopy and tomography to monitor structural gradients in catalytic reactors and catalyst preparation with micrometre resolution but also the possibility to follow structural changes in the sub-100 nm regime. Moreover, the potential of the new synchrotron radiation sources with higher brilliance, recent milestones in focusing of hard X-rays as well as spatiotemporal studies are highlighted. The tutorial review concludes with a view on future developments in the field of X-ray microscopy that will have strong impact on the understanding of catalysts in the future and should be combined with in situ electron microscopic studies on the nanoscale and other spectroscopic studies like microRaman, microIR and microUV-vis on the macroscale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atom-Resolved Imaging of Dynamic Shape Changes in Supported Copper Nanocrystals
Hansen, P. L., Wagner, J. B., Helveg, S., Rostrup-Nielsen, J. R., Clausen, B. S., & Topsøe, H. (2002) · Science · doi:10.1126/science.1069325 · Cited by 1,261
Cited by
Probing zeolites by vibrational spectroscopies
Bordiga, S., Lamberti, C., Bonino, F., Travert, A., & Thibault-Starzyk, F. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00396b · Cited by 460
Kalz, K. F., Kraehnert, R., Dvoyashkin, M., Dittmeyer, R., Gläser, R., Krewer, U., Reuter, K., & Grunwaldt, J. (2017) · ChemCatChem · doi:10.1002/cctc.201600996 · Cited by 458
Self-citationXu, G., Amine, R., Abouimrane, A., Che, H., Dahbi, M., Ma, Z., Saadoune, I., Alami, J., Mattis, W. L., Pan, F., et al. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201702403 · Cited by 287
Metadata
- Authors
- Grunwaldt, J.-D., & Schroer, C. G.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 12
- Pages
- 4741
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2138778218
- Cited by
- 181
- References
- 1
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hard and soft X-ray microscopy and tomography in catalysis: bridging the different time and length scales. https://app.cochat.ai/papers/10.1039/c0cs00036a
- The paper
- Grunwaldt, J.-D., & Schroer, C. G. (2010). Hard and soft X-ray microscopy and tomography in catalysis: bridging the different time and length scales. Chemical Society Reviews. https://doi.org/10.1039/c0cs00036a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.