CoChat

Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells

Chen, Beibei, Heng, Shujing, Peng, Hanyong, Hu, Bin, Yu, Xu, Zhang, Zhiling, Pang, Daiwen, Yue, Xin, Zhu, Ying · 2010 · Journal of Analytical Atomic Spectrometry
Cited by 104

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Quantitative analysis of trace levels of heavy metals in human cells is critical to environmental and toxicological research. We describe here a new strategy of determining ultratrace levels of cadmium, lead, and mercury in cultured cells. It involves the integration of cell sample introduction and magnetic nanoparticle solid phase microextraction (MSPME) on a microfluidic chip, combined with electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS) detection. γ-mercaptopropyltrimethoxysilane (γ-MPTS) modified silica-coated magnetic nanoparticles were synthesized and demonstrated for the microextraction of Cd, Pb, and Hg. Under an external magnetic field, these magnetic nanoparticles self-assembled in microchannels to form a solid phase packed column. The formation mechanism of the on-chip magnetic solid phase packed column and the main factors influencing the packing and analytical performance were investigated. Under the optimized conditions, MSPME enabled enrichment of Cd, Hg, and Pb by a factor of >40, and resulted in improved limits of detection for Cd (0.72 ng L−1), Hg (0.86 ng L−1), and Pb (1.12 ng L−1) using ETV-ICP-MS. Quantitative analyses of trace Cd, Hg and Pb in HepG2 cells were achieved by applying the microfluidic system that integrated cell rupture, mixing, magnetic extraction and elution into one device, followed by ultrasensitive detection by ETV-ICP-MS, which required only a microlitre amount of sample. Analysis of approximately 5000 cells revealed that the average amounts of Cd, Hg and Pb in a single HepG2 cell were of the order of a few femtograms, and that the cellular levels increased with increasing concentrations of these metals in cell cultures. The concentrations of Cd, Hg, and Pb detectable in HepG2 cells were several orders of magnitude lower than their IC50 values, suggesting that the technique is potentially useful for measuring these heavy metals in studies of chronic metal toxicity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c0ja00003e

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
Chen, B., Heng, S., Peng, H., Hu, B., Yu, X., Zhang, Z., Pang, D., Yue, X., & Zhu, Y.
Venue
Journal of Analytical Atomic Spectrometry
Published
2010
Volume
25
Issue
12
Pages
1931
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2017850343
Cited by
104
References
2
FWCI
9.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.