The DOI matches its Crossref record.
Selective identification, characterization and determination of dissolved silver(i) and silver nanoparticles based on single particle detection by inductively coupled plasma mass spectrometry
Open accessAbstract
The different behaviours of dissolved silver and silver nanoparticles under ICP-MS single particle detection conditions have been used to differentiate directly between both forms of silver in aqueous samples. Suspensions containing silver nanoparticles at number concentrations below 109 L−1 and/or dissolved Ag(I) are introduced into the ICP-MS by conventional pneumatic nebulization and measured with a time resolution of 5 ms. Each silver nanoparticle is converted in the ICP into a packet of ions, which are detected as a single pulse, whose intensity is proportional to the number of silver atoms in the nanoparticle, whereas dissolved silver produces pulses of averaged constant intensity. The frequency plots with respect to the intensity measured for each pulse show independent distributions for dissolved silver and silver nanoparticles, whose profiles are also different (Poisson and lognormal, respectively). Size limits of detection for pure Ag nanoparticles of 18 nm, equivalent to a silver mass of 32 ag, were obtained. Number concentration limits of detection of 1 × 104 L−1 can be achieved. A methodological approach for identification, characterization and determination of mass and number concentration of dissolved Ag(I) and silver nanoparticles at environmentally relevant concentrations is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle Size Detection Limits by Single Particle ICP-MS for 40 Elements
Lee, S., Bi, X., Reed, R. B., Ranville, J. F., Herckes, P., & Westerhoff, P. (2014) · Environmental Science & Technology · doi:10.1021/es502422v · Cited by 448
Environmental Mass Spectrometry: Emerging Contaminants and Current Issues
Richardson, S. D. (2012) · Analytical Chemistry · doi:10.1021/ac202903d · Cited by 323
De la Calle, I., Menta, M., & Séby, F. (2016) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2016.09.007 · Cited by 99
Metadata
- Authors
- Laborda, F., Jiménez-Lamana, J., Bolea, E., & Castillo, J. R.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 26
- Issue
- 7
- Pages
- 1362
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2009201464
- Cited by
- 368
- References
- 0
- FWCI
- 25.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective identification, characterization and determination of dissolved silver(i) and silver nanoparticles based on single particle detection by inductively coupled plasma mass spectrometry. https://app.cochat.ai/papers/10.1039/c0ja00098a
- The paper
- Laborda, F., Jiménez-Lamana, J., Bolea, E., & Castillo, J. R. (2011). Selective identification, characterization and determination of dissolved silver(i) and silver nanoparticles based on single particle detection by inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/c0ja00098a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.