The DOI matches its Crossref record.
Preparation and characterization of NiO–Ag nanofibers, NiO nanofibers, and porous Ag: towards the development of a highly sensitive and selective non-enzymatic glucose sensor
Abstract
Following a facile two-step synthesis route, NiO–Ag hybrid nanofibers, NiO nanofibers, and porous Ag were prepared. Scanning electron microscopy and transmission electron microscopy were employed to characterize the morphology of the as-prepared samples. Fourier transform infrared spectroscopy was used to confirm the complete degradation of the polymer matrix and the conversion of metal salts to metal oxides. X-Ray diffraction and X-ray photoelectron spectroscopy were performed to investigate the crystal structures and compositions of the final products. The as-prepared samples were then applied to construct non-enzymatic sensors for glucose detection. The NiO–Ag hybrid nanofiber-based sensor shows much higher sensitivity, lower detection limit and wider linear range in glucose detection compared to the NiO nanofibers or the porous Ag based sensor. A synergistic effect was achieved between NiO and Ag. High selectivity against uric acid and ascorbic acid was also achieved from the NiO–Ag nanofibers and NiO nanofiber-based sensors at an applied potential of 0.6 V. A mechanism of the excellent selectivity was proposed for the first time. The application of NiO–Ag nanofibers for selective glucose detection was also demonstrated using human serum sample, and the result is in good agreement with that of commercial glucose meter. The excellent performance of the developed inorganic nanofiber-based glucose sensor, combined with good reproducibility, low cost and inherent stability of inorganic materials, indicates great commercial value in clinical diagnosis of diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires
Zhang, Y., Su, L., Manuzzi, D., de los Monteros, H. V. E., Jia, W., Huo, D., Hou, C., & Lei, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.006 · Cited by 321
Self-citationCuO nanowires based sensitive and selective non-enzymatic glucose detection
Zhang, Y., Liu, Y., Su, L., Zhang, Z., Huo, D., Hou, C., & Lei, Y. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.08.096 · Cited by 260
Self-citation
Metadata
- Authors
- Ding, Y., Wang, Y., Su, L., Zhang, H., & Lei, Y.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 20
- Issue
- 44
- Pages
- 9918
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2061358575
- Cited by
- 195
- References
- 0
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation and characterization of NiO–Ag nanofibers, NiO nanofibers, and porous Ag: towards the development of a highly sensitive and selective non-enzymatic glucose sensor. https://app.cochat.ai/papers/10.1039/c0jm01968b
- The paper
- Ding, Y., Wang, Y., Su, L., Zhang, H., & Lei, Y. (2010). Preparation and characterization of NiO–Ag nanofibers, NiO nanofibers, and porous Ag: towards the development of a highly sensitive and selective non-enzymatic glucose sensor. Journal of Materials Chemistry. https://doi.org/10.1039/c0jm01968b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.