The DOI matches its Crossref record.
Tumour cell identification by means of Raman spectroscopy in combination with optical traps and microfluidic environments
Abstract
Raman spectroscopy has been recognized to be a powerful tool for label-free discrimination of cells. Sampling methods are under development to utilize the unique capabilities to identify cells in body fluids such as saliva, urine or blood. The current study applied optical traps in combination with Raman spectroscopy to acquire spectra of single cells in microfluidic glass channels. Optical traps were realized by two 1070 nm single mode fibre lasers. Microflows were controlled by a syringe pump system. A novel microfluidic glass chip was designed to inject single cells, modify the flow speed, accommodate the laser fibres and sort cells after Raman based identification. Whereas the integrated microchip setup used 514 nm for excitation of Raman spectra, a quartz capillary setup excited spectra with 785 nm laser wavelength. Classification models were trained using linear discriminant analysis to differentiate erythrocytes, leukocytes, acute myeloid leukaemia cells (OCI-AML3), and breast tumour cells BT-20 and MCF-7 with accuracies that are comparable with previous Raman experiments of dried cells and fixed cells in a Petri dish. Implementation into microfluidic environments enables a high degree of automation that is required to improve the throughput of the approach for Raman activated cell sorting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman Spectroscopy of Biological Tissues
Talari, A. C. S., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.923902 · Cited by 739
Kong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Raman Spectroscopy of Blood and Blood Components
Atkins, C. G., Buckley, K., Blades, M. W., & Turner, R. F. B. (2017) · Applied Spectroscopy · doi:10.1177/0003702816686593 · Cited by 292
Advantages and limitations of Raman spectroscopy for molecular diagnostics: an update
Eberhardt, K., Stiebing, C., Matthäus, C., Schmitt, M., & Popp, J. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.1036744 · Cited by 282
Self-citationZhang, Y., Chang, K., Ogunlade, B., Herndon, L., Tadesse, L. F., Kirane, A. R., & Dionne, J. A. (2024) · ACS Nano · doi:10.1021/acsnano.4c04282 · Cited by 83
Metadata
- Authors
- Dochow, S., Krafft, C., Neugebauer, U., Bocklitz, T., Henkel, T., Mayer, G., Albert, J., & Popp, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 8
- Pages
- 1484
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2065311323
- Cited by
- 197
- References
- 0
- FWCI
- 13.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tumour cell identification by means of Raman spectroscopy in combination with optical traps and microfluidic environments. https://app.cochat.ai/papers/10.1039/c0lc00612b
- The paper
- Dochow, S., Krafft, C., Neugebauer, U., Bocklitz, T., Henkel, T., Mayer, G., Albert, J., & Popp, J. (2011). Tumour cell identification by means of Raman spectroscopy in combination with optical traps and microfluidic environments. Lab on a Chip. https://doi.org/10.1039/c0lc00612b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.