The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
All-solid-state potassium-selective electrode using graphene as the solid contact
Abstract
Graphene sheets are used for the first time to fabricate a new type of solid-contact ion-selective electrode (SC-ISE) as the intermediate layer between an ionophore-doped solvent polymeric membrane and a glassy carbon electrode. The new transducing layer was characterized by transmission electron microscopy, scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The performance of the new K(+-)selective electrodes was examined by a potentiometric water layer test, potentiometric measurements, and current reversal chronopotentiometry. The obtained potentiometric sensors were characterized with a calibration line of slope close to Nernstian (59.2 mV/decade) within the activity from 10(-4.5) to 0.1 M. The high capacitance of the graphene solid contacts results in a signal that is stable over one week. The short response time is less than 10 s for activities higher than 10(-5) M. The potential drift of the electrodes was calculated from the slope of the curves at longer times (ΔE/Δt = 1.2 × 10(-5) V s(-1) (I = 1 nA) and ΔE/Δt = 5.5 × 10(-5) V s(-1) (I = 5 nA)). All the results indicate that graphene is a promising material for use as a transducer layer for SC-ISEs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Metadata
- Authors
- Li, F., Ye, J., Zhou, M., Gan, S., Zhang, Q., Han, D., & Niu, L.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 3
- Pages
- 618-623
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2140802240
- Cited by
- 178
- References
- 1
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: All-solid-state potassium-selective electrode using graphene as the solid contact. https://app.cochat.ai/papers/10.1039/c1an15705a
- The paper
- Li, F., Ye, J., Zhou, M., Gan, S., Zhang, Q., Han, D., & Niu, L. (2012). All-solid-state potassium-selective electrode using graphene as the solid contact. The Analyst. https://doi.org/10.1039/c1an15705a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.