Temperature-controlled ionic liquid-based dispersive liquid-phase microextraction, preconcentration and quantification of nano-amounts of silver ion by using disulfiram as complexing agent
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microextraction and preconcentration of Ag+ by using temperature-controlled ionic liquid-based dispersive liquid-phase microextraction (TCIL-DLPME) method is reported. It was found that tetraethylthiuram disulfide (disulfiram) dissolved in 1-hexyl-3-methylimidazolium hexaflorophosphate, [C6mim][PF6] was useful as extracting media. Graphite furnace atomic absorption spectroscopy was used to quantify Ag+. To improve extraction efficiency, different experimental factors, such as volume of ionic liquid phase, pH and volume of aqueous solution, cooling and centrifugation periods, and dissolving temperature were investigated. The calibration curve was linear in the concentration range of 6.0–100.0 ng l−1 of Ag+. Relative standard deviation (n = 7), detection limit, and preconcentration factor for determination of Ag+ were found to be 4.5%, 5.2 ng l−1, and 120, respectively. The method was successfully applied for determination of Ag+ in drinking water and hair samples. Percent recoveries for solutions containing Ag+ indicated that chemical interferences by selected anions (NO3−, Cl−, I−, Br− and citrate) or cations (Ni2+, Cu2+, Mg2+, Zn2+, Pb2+, Ca2+, Co2+, Hg2+, Na+ and Mn2+) in solution were minimal or non-existent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Cited by
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
“Thus, solid samples analyzed include roots [52], powdered pharmacy tablets [56], flours, potatoes and apples [67], and hair [68].”
BackgroundRecent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Metadata
- Authors
- Absalan, G., Akhond, M., Sheikhian, L., & Goltz, D. M.
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 3
- Issue
- 10
- Pages
- 2354
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2034337962
- Cited by
- 24
- References
- 1
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.