The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
“Turn-on” fluorescent sensing with “reactive” probes
Open accessAbstract
Chemical probes are valuable tools for the investigation of biochemical processes, diagnosis of disease markers, detection of hazardous compounds, and other purposes. Therefore, the development of chemical probes continues to grow through various approaches with different disciplines and design strategies. Fluorescent probes have received much attention because they are sensitive and easy-to-operate, in general. To realize desired selectivity toward a given analyte, the recognition site of a fluorescent probe is designed in such a way to maximize the binding interactions, usually through weak molecular forces such as hydrogen bonding, toward the analyte over other competing ones. In addition to such a supramolecular approach, the development of fluorescent probes that sense analytes through chemical reactions has witnessed its usefulness for achieving high selectivity, in many cases, superior to that obtainable by the supramolecular approach. Creative incorporations of the reactive groups to latent fluorophores have provided novel chemical probes for various analytes. In this feature article, we overview the recent progress in the development of turn-on fluorescent probes that are operating through chemical reactions triggered by target analytes. Various chemical reactions have been implemented in the development of many reactive probes with very high selectivity and sensitivity toward target analytes. A major emphasis has been focused on the type of chemical reactions utilized, with the hope that further explorations can be made with new chemical reactions to develop reactive probes useful for various applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Detection and Imaging of Nitric Oxide with Novel Fluorescent Indicators: Diaminofluoresceins
Kojima, H., Nakatsubo, N., Kikuchi, K., Kawahara, S., Kirino, Y., Nagoshi, H., Hirata, Y., & Nagano, T. (1998) · Analytical Chemistry · doi:10.1021/ac9801723 · Cited by 1,389
Setsukinai, K.-I., Urano, Y., Kakinuma, K., Majima, H. J., & Nagano, T. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m209264200 · Cited by 1,301
Sensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
A Fluorometric Assay for the Measurement of Nitrite in Biological Samples
Misko, T. P., Schilling, R. J., Salvemini, D., Moore, W. M., & Currie, M. G. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1449 · Cited by 1,027
A Long-Wavelength Fluorescent Chemodosimeter Selective for Cu(II) Ion in Water
Dujols, V., Ford, F., & Czarnik, A. W. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971221g · Cited by 987
Cited by
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Bright Building Blocks for Chemical Biology
Lavis, L. D., & Raines, R. T. (2014) · ACS Chemical Biology · doi:10.1021/cb500078u · Cited by 536
Reaction-based BODIPY probes for selective bio-imaging
Kolemen, S., & Akkaya, E. U. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.021 · Cited by 357
Reactivity-Based Organic Theranostic Bioprobes
Kenry, Chong, K. C., & Liu, B. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00356 · Cited by 99
Metadata
- Authors
- Eun Jun, M., Roy, B., & Han Ahn, K.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 47
- Issue
- 27
- Pages
- 7583
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2137697952
- Cited by
- 434
- References
- 81
- FWCI
- 21.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Turn-on” fluorescent sensing with “reactive” probes. https://app.cochat.ai/papers/10.1039/c1cc00014d
- The paper
- Eun Jun, M., Roy, B., & Han Ahn, K. (2011). “Turn-on” fluorescent sensing with “reactive” probes. Chemical Communications. https://doi.org/10.1039/c1cc00014d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.