Cited by 400Microfluidic and Bio-sensing TechnologiesMicrofluidic and Capillary Electrophoresis ApplicationsCancer Genomics and Diagnostics

Microchip-based immunomagnetic detection of circulating tumor cells

Open access
Hoshino, Kazunori, Huang, Yu-Yen, Lane, Nancy, Huebschman, Michael, Uhr, Jonathan W., Frenkel, Eugene P., Zhang, Xiaojing·2011·Lab on a Chip

Abstract

Screening for circulating tumor cells (CTCs) in blood has been an object of interest for evidence of progressive disease, status of disease activity, recognition of clonal evolution of molecular changes and for possible early diagnosis of cancer. We describe a new method of microchip-based immunomagnetic CTC detection, in which the benefits of both immunomagnetic assay and the microfluidic device are combined. As the blood sample flows through the microchannel closely above arrayed magnets, cancer cells labeled with magnetic nanoparticles are separated from blood flow and deposited at the bottom wall of the glass coverslip, which allows direct observation of captured cells with a fluorescence microscope. A polydimethylsiloxane (PDMS)-based microchannel fixed on a glass coverslip was used to screen blood samples. The thin, flat dimensions of the microchannel, combined with the sharp magnetic field gradient in the vicinity of arrayed magnets with alternate polarities, lead to an effective capture of labeled cells. Compared to the commercially available CellSearch™ system, fewer (25%) magnetic particles are required to achieve a comparable capture rate, while the screening speed (at an optimal blood flow rate of 10 mL h(-1)) is more than five times faster than those reported previously with a microchannel-based assay. For the screening experiment, blood drawn from healthy subjects into CellSave™ tubes was spiked with cultured cancer cell lines of COLO205 and SKBR3. The blood was then kept at room temperature for 48 hours before the screening, emulating the actual clinical cases of blood screening. Customized Fe(3)O(4) magnetic nanoparticles (Veridex Ferrofluid™) conjugated to anti-epithelial cell adhesion molecule (EpCAM) antibodies were introduced into the blood samples to label cancer cells, and the blood was then run through the microchip device to capture the labelled cells. After capture, the cells were stained with fluorescent labelled anti-cytokeratin, DAPI and anti-CD45. Subsequent immunofluorescence images were taken for the captured cells, followed by comprehensive computer aided analysis based on fluorescence intensities and cell morphology. Rare cancer cells (from ∼1000 cells down to ∼5 cells per mL) with very low tumor cell to blood cell ratios (about 1 : 10(7) to 10(9), including red blood cells) were successfully detected. Cancer cell capture rates of 90% and 86% were demonstrated for COLO205 and SKBR3 cells, respectively.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c1lc20270g

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 36 · Cited by 400

Research works printed but not linked: 27

  1. [1]Kaiser J Cancer’s Circulation Problem Science 2010 327 1072 1074 20185704
  2. [2]Paterlini-Brechot P Linda Benali N Circulating tumor cells (CTC) detection: Clinical impact and future directions Cancer Lett 2007 253 180 204 17314005
  3. [3]Mostert B Sleijfer S Foekens JA Gratama JW Circulating tumor cells (CTCs): Detection methods and their clinical relevance in breast cancer Cancer Treat. Rev 2009 35 463 474 19410375
  4. [5]Fehm T Sagalowsky A Clifford E Beitsch P Saboorian H Euhus D Meng S Morrison L Tucker T Lane N Ghadimi BM Heselmeyer-Haddad K Ried T Rao C Uhr J Cytogenetic evidence that circulating epithelial cells in patients with carcinoma are malignant Clin. Cancer Res 2002 8 2073 2084 12114406
  5. [6]Budd GT Circulating tumor cells versus imaging–predicting overall survival in metastatic breast cancer Clin. Cancer Res 2006 12 6403 6409 17085652
  6. [7]Miller MC Doyle GV Terstappen LWMM Significance of Circulating Tumor Cells Detected by the CellSearch System in Patients with Metastatic Breast Colorectal and Prostate Cancer J. Oncol 2010 2010 1 8 PMC2793426 20016752
  7. [8]Cohen S Relationship of Circulating Tumor Cells to Tumor Response, Progression-Free Survival, and Overall Survival in Patients With Metastatic Colorectal Cancer J. Clin. Oncol 2008 26 3213 3221 18591556
  8. [9]He W Quantitation of circulating tumor cells in blood samples from ovarian and prostate cancer patients using tumor-specific fluorescent ligands Int. J. Cancer 2008 123 1968 1973 18661519 PMC2778289
  9. [10]Gross HJ Verwer B Houck D Hoffman RA Recjtenwald D Model study detecting breast cancer cells in peripheral blood mononuclear cells at frequencies as low as 10-7 Proc. Natl. Acad. Sci. USA 1995 92 537 541 7831325 PMC42776
  10. [11]Lin HK Portable filter-based microdevice for detection and characterization of Circulating Tumor Cells Clin. Cancer Res 2010 16 5011 5018 20876796 PMC2955786
  11. [12]Tan SJ Yobas L Lee GYH Ong CN Lim CT Microdevice for the isolation and enumeration of cancer cells from blood Biomed. Microdevices 2009 11 883 892 19387837
  12. [13]Hansel TT De Vries IJM Iff T Rihs S Wandzilak M Betz S Blaser K Walker C An improved immunomagnetic procedure for the isolation of highly purified human blood eosinophils J. Immunol. Methods 1991 145 105 110 1662676
  13. [14]Racila E Euhus D Weiss AJ Rao C McConnell J Terstappen Leon W. M. M Uhr JW Detection and characterization of carcinoma cells in the blood Proc. Natl. Acad. Sci.USA 1998 4589 4594 9539782 PMC22534
  14. [15]Balasubramanian P Yang L Lang JC Jatana KR Schuller D Agrawal A Zborowski M Chalmers JJ Confocal Images of Circulating Tumor Cells Obtained Using a Methodology and Technology That Removes Normal Cells Molecul. Pharm 2009 6 1402 1408 PMC2829323 19445481
  15. [16]Talasaz AH Isolating highly enriched populations of circulating epithelial cells and other rare cells from blood using a magnetic sweeper device Proc. Natl. Acad. Sci.USA 2009 106 3970 3975 19234122 PMC2645911
  16. [18]Nagrath S Isolation of rare circulating tumour cells in cancer patients by microchip technology Nature 2007 450 1235 1239 18097410 PMC3090667
  17. [19]Stott SL Isolation of circulating tumor cells using a microvortex-generating herringbone-chip Proc. Natl. Acad. Sci.USA 2010 107 1012539 PMC2972993 20930119
  18. [20]Pamme N Magnetism and microfluidics Lab Chip 2006 6 24 38 16372066
  19. [21]Earhart CM Wilson RJ White RL Pourmand N Wang SX Microfabricated magnetic sifter for high-throughput and high-gradient magnetic separation J. Magn. Magn., Mater 2009 321 1436 1439 20161248 PMC2707938
  20. [23]Xia N Hunt TP Mayers BT Alsberg E Whitesides GM Westervelt RM Ingber DE Combined microfluidic-micromagnetic separation of living cells in continuous flow Biomed Microdev 2006 8 299 308 17003962
  21. [24]Yung CW Fiering J Muellerb AJ Ingber DE Micromagnetic–microfluidic blood cleansing device Lab Chip 2009 9 1171 1177 19370233
  22. [26]Furdui VI Harrison DJ Immunomagnetic T cell capture from blood for PCR analysis using microfluidic systems Lab Chip 2004 4 614 15570374
  23. [27]Zborowski M Fuh CB Green R Sun L Chalmers JJ Analytical Magnetopheresis of Ferritin-labeled Lymphocytes Anal. Chem 1995 67 3702 3712 8644920
  24. [28]Fan B Zborowski M Moore LR Detection of rare MCF-7 breast carcinoma cells from mixtures of human peripheral leukocytes by magnetic deposition analysis Cytometry 1999 36 294 302 10404144
  25. [29]Karl S David M Moore L Grimberg BT Michon P Muellter I Zborowski M Zimmerman PA Enhanced detection of grametocytes by magnetic deposition microscopy predicts higher potential for Palsmodium falciparum transmission Malar. J 2008 7 66 18439240 PMC2373791
  26. [30]Moore LR Fujioka H Williams PS Chalmers JJ Grimberg B Zimmerman P Zborowski M Hemoglobin degradation in malaria-infected erythrocytes determined from live cell magnetophoresis FASEB J 2006 20 747 749 16461330 PMC3728832
  27. [31]Rao CG Chianese D Doyle GV Miller MC Russell T Sanders RA Jr Terstappen LW Expression of epithelial cell adhesion molecule in carcinoma cells present in blood and primary and metastatic tumors Int J. Oncol 2005 27 49 57 15942643

Authors
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X.
Affiliations
  • The University of Texas at Austin (US)
  • Harold C. Simmons Comprehensive Cancer Center (US)
Corresponding author
Hoshino, Kazunori
Venue
Lab on a Chip
Published
2011
Volume
11
Issue
20
Pages
3449
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2038371089
Cited by
400
References
36
Citations by year
2026: 5 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 24 · 2021: 23 · 2020: 28 · 2019: 32 · 2018: 32 · 2017: 37 · 2016: 42 · 2015: 44 · 2014: 34 · 2013: 34 · 2012: 23
FWCI
17.63
Type
journal article
Language
en
Open access
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • University of Texas at Austin
  • National Institutes of Health
  • University of Colorado Boulder
  • National Cancer Institute (R01CA139070)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer Genomics and Diagnostics
Keywords
circulating tumor cells, immunomagnetic separation, microfluidics, magnetic nanoparticles, EpCAM, Fe3O4 nanoparticles, PDMS microchannel, cancer cell detection, CellSearch comparison, COLO 205, SKBR3, fluorescence imaging, rare cell capture, cancer screening
MeSH terms
Cell Count, Cell Separation, Humans, Immunoassay, Neoplastic Cells, Circulating, Cell Line, Tumor, Lab-On-A-Chip Devices, Magnets

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review