The inherent problem of transflection-mode infrared spectroscopic microscopy and the ramifications for biomedical single point and imaging applications
Open accessAbstract
Transflection-mode FTIR spectroscopy has become a popular method of measuring spectra from biomedical and other samples due to the relative low cost of substrates compared to transmission windows, and a higher absorbance due to a double pass through the same sample approximately doubling the effective path length. In this publication we state an optical description of samples on multilayer low-e reflective substrates. Using this model we are able to explain in detail the so-called electric-field standing wave effect and rationalise the non-linear change in absorbance with sample thickness. The ramifications of this non-linear change, for imaging and classification systems, where a model is built from tissue sectioned at a particular thickness and compared with tissue of a different thickness are discussed. We show that spectra can be distorted such that classification fails leading to inaccurate tissue segmentation which may have subsequent implications for disease diagnostics applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
The citation lists are queued
They are fetched later and appear here then.
References 40 · Cited by 130
Research works printed but not linked: 2
- E. Hecht , Optics, Pearson Education, Addison-Wesley Series in Physics, 4th edn, 1974
- Kramers, 1927, Atti. congr. intern. fisici, Como, 2, 545
Metadata
- Authors
- Bassan, P., Lee, J., Sachdeva, A., Pissardini, J., Dorling, K. M., Fletcher, J. S., Henderson, A., & Gardner, P.
- Affiliations
- University of Manchester (GB)
- Corresponding author
- Gardner, Peter
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 1
- Pages
- 144-157
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2041551651
- Cited by
- 130
- References
- 40
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 6 · 2021: 7 · 2020: 8 · 2019: 7 · 2018: 10 · 2017: 10 · 2016: 12 · 2015: 25 · 2014: 17 · 2013: 20
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Keywords
- spectral distortion, tissue classification, tissue segmentation, disease diagnosis
- MeSH terms
- Absorption, Cytosine, Humans, Male, Microscopy, Prostate, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The inherent problem of transflection-mode infrared spectroscopic microscopy and the ramifications for biomedical single point and imaging applications. https://app.cochat.ai/papers/10.1039/c2an36090j
- The paper
- Bassan, P., Lee, J., Sachdeva, A., Pissardini, J., Dorling, K. M., Fletcher, J. S., Henderson, A., & Gardner, P. (2013). The inherent problem of transflection-mode infrared spectroscopic microscopy and the ramifications for biomedical single point and imaging applications. The Analyst. https://doi.org/10.1039/c2an36090j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.