The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Amide I vibrational mode suppression in surface (SERS) and tip (TERS) enhanced Raman spectra of protein specimens
Open accessAbstract
Surface- and tip-enhanced Raman spectroscopy (SERS and TERS) are modern spectroscopic techniques, which are becoming widely used and show a great potential for the structural characterisation of biological systems. Strong enhancement of the Raman signal through localised surface plasmon resonance enables chemical detection at the single-molecule scale. Enhanced Raman spectra collected from biological specimens, such as peptides, proteins or microorganisms, were often observed to lack the amide I band, which is commonly used as a marker for the interpretation of the secondary protein structure. The cause of this phenomenon was unclear for many decades. In this work, we investigated this phenomenon for native insulin and insulin fibrils using both TERS and SERS and compared these spectra to the spectra of well-defined homo peptides. The results indicate that the appearance of the amide I Raman band does not correlate with the protein aggregation state, but is instead determined by the size of the amino acid side chain. For short model peptides, the absence of the amide I band in TERS and SERS spectra correlates with the presence of a bulky side chain. Homo-glycine and -alanine, which are peptides with small side chain groups (H and CH(3), respectively), exhibited an intense amide I band in almost 100% of the acquired spectra. Peptides with bulky side chains, such as tyrosine and tryptophan, exhibited the amide I band in 70% and 31% of the acquired spectra, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Cited by
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Infrared and Raman chemical imaging and spectroscopy at the nanoscale
Kurouski, D., Dazzi, A., Zenobi, R., & Centrone, A. (2020) · Chemical Society Reviews · doi:10.1039/c8cs00916c · Cited by 324
Self-citationXu, L.-J., Zong, C., Zheng, X.-S., Hu, P., Feng, J.-M., & Ren, B. (2014) · Analytical Chemistry · doi:10.1021/ac403974n · Cited by 301
Potential of Raman spectroscopic techniques to study proteins
Kuhar, N., Sil, S., & Umapathy, S. (2021) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.119712 · Cited by 290
Exploring the structure and formation mechanism of amyloid fibrils by Raman spectroscopy: a review
Kurouski, D., Van Duyne, R. P., & Lednev, I. K. (2015) · The Analyst · doi:10.1039/c5an00342c · Cited by 268
Self-citation
Metadata
- Authors
- Kurouski, D., Postiglione, T., Deckert-Gaudig, T., Deckert, V., & Lednev, I. K.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 6
- Pages
- 1665
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2021768892
- Cited by
- 182
- References
- 1
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.