Cited by 20Analytical chemistry methods developmentForensic Toxicology and Drug AnalysisAnalytical Methods in Pharmaceuticals

Simultaneous determination of amphetamine and related compounds in human urine using ultrasound-assisted emulsification microextraction and gas chromatography

Rezaee, Mohammad, Mashayekhi, Hossein Ali, Garmaroudi, Shirin Sadeghi·2012·Analytical Methods

Abstract

3,4-methylenedioxymethylamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylamphetamine (MDEA) and 3,4-methylenedioxypropylamphetamine (MDPA) were extracted from human urine by using ultrasound-assisted emulsification microextraction (USAEME) method based on applying low density organic solvents followed by gas chromatographic analysis with flame ionization detection. Fourteen microliters of toluene was injected slowly into a 12 mL home-designed centrifuge glass vial containing a sample without salt addition that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and 2 μL of separated toluene was injected into a gas chromatographic system equipped with a flame ionization detector (GC-FID) for analysis. In order to improve the extraction efficiency, experimental parameters affecting the extraction efficiency, including type and volume of extraction solvent, pH value of sample, extraction time and temperature were investigated. Under the optimal conditions, the linear dynamic range was in the range of 0.5–500 μg L−1 for MDEA and MDPA and 1.0–500 μg L−1 for MDA and MDMA with limits of detection (LODs) in the range of 0.2 to 0.4 μg L−1. The results indicate that the developed method is rapid, accurate and sensitive and can be used for the simultaneous determination of MDA, MDMA, MDEA and MDPA in urine samples.

Integrity signals

Registry

Crossref · 10.1039/c2ay25461a

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rezaee, M., Mashayekhi, H. A., & Garmaroudi, S. S.
Affiliations
  • Islamic Azad University, Tehran (IR)
  • Islamic Azad University Tonekabon (IR)
Corresponding author
Mashayekhi, Hossein Ali
Venue
Analytical Methods
Published
2012
Volume
4
Issue
10
Pages
3212
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W2082196034
Cited by
20
References
2
Citations by year
2022: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 1
FWCI
2.50
Type
journal article
Language
en
Open access
closed
Locations
Analytical Methods (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
amphetamine, MDMA, MDA, methyldiethanolamine, 3,4-methylenedioxyamphetamine, urine, ultrasound-assisted emulsification microextraction, sample preparation, simultaneous determination, extraction optimization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review