The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Physicochemical properties determined by ΔpKa for protic ionic liquids based on an organic super-strong base with various Brønsted acids
Abstract
Neutralization of an organic super-strong base, 1,8-diazabicyclo-[5,4,0]-undec-7-ene (DBU), with different Brønsted acids affords a novel series of protic ionic liquids (PILs) with wide variations in the ΔpK(a) of the constituent amine and acids. The physicochemical properties of these PILs, such as thermal properties, density, conductivity, viscosity, self-diffusion coefficient, vibrational stretching frequency, and (1)H-chemical shifts of the N-H bond, have been studied in detail. The generated PILs have melting temperatures below 100 °C, and six are liquids at ambient temperatures. Thermogravimetric analyses (TGA) conducted under isothermal and programmed heating conditions have shown that PILs with ΔpK(a)≥ 15 exhibit good thermal stability similar to aprotic ionic liquids. For instance, PILs with ΔpK(a) > 20 show remarkably high short-term thermal stability up to ca. 450 °C under a nitrogen atmosphere. The viscosity, ionic conductivity, and molar conductivity of the PILs fit well with the Vogel-Fulcher-Tamman equation for their dependencies on temperature. The relative cationic and anionic self-diffusion coefficients of the PILs estimated by the pulsed-field gradient spin-echo (PGSE) NMR method appear to be dependent on the structure and strength of the Brønsted acids. Evaluation of the ionicity based on both the Walden plot and PGSE-NMR revealed that it increases until ΔpK(a) becomes 15 for the PILs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Byrne, N., Wang, L.-M., Belieres, J.-P., & Angell, C. A. (2007) · Chem. Commun. · doi:10.1039/b618943a · Cited by 223
Cited by
Application of Ionic Liquids to Energy Storage and Conversion Materials and Devices
Watanabe, M., Thomas, M. L., Zhang, S., Ueno, K., Yasuda, T., & Dokko, K. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00504 · Cited by 1,667
Self-citationDeng, Y., Xie, Y., Zou, K., & Ji, X. (2016) · Journal of Materials Chemistry A · doi:10.1039/c5ta08620e · Cited by 997
Amarasekara, A. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00763 · Cited by 842
Zhang, S., Zhang, J., Zhang, Y., & Deng, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00509 · Cited by 659
Ionic liquids for energy, materials, and medicine
Smiglak, M., Pringle, J. M., Lu, X., Han, L., Zhang, S., Gao, H., MacFarlane, D. R., & Rogers, R. D. (2014) · Chem. Commun. · doi:10.1039/c4cc02021a · Cited by 509
Metadata
- Authors
- Miran, M. S., Kinoshita, H., Yasuda, T., Susan, M. A. B. H., & Watanabe, M.
- Venue
- Physical Chemistry Chemical Physics
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 14
- Issue
- 15
- Pages
- 5178
- ISSN
- 1463-9076 (ISSN-L)
- 1463-9084
- OpenAlex
- W1992591062
- Cited by
- 234
- References
- 1
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.