The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A prototype of a new inductively coupled plasma time-of-flight mass spectrometer providing temporally resolved, multi-element detection of short signals generated by single particles and droplets
Abstract
A prototype inductively coupled plasma time-of-flight mass spectrometer (ICPTOFMS) for time resolved measurements of transient signals in the microsecond regime is described in this work. Analytical figures of merit for the prototype are given for both liquid nebulization and single droplet introduction and are compared to a conventional quadrupole-based ICPMS using the same ICP source and vacuum interface. Quasi-simultaneous detection at a time resolution of 33 μs of the prototype ICPTOFMS allows multi-isotope monitoring of short signals (200–500 μs duration) generated from individual droplets and particles. The capabilities of the instrument for the analysis of single nanoparticles are studied using microdroplets consisting of a multi-element standard solution and containing 114 nm Au particles. The detection efficiencies for Ag and Au, calculated from the response of individual droplets and particles, are similar to those of the quadrupole-based instrument and amount to 1.3 × 10−6 ions per atom and 3.1 × 10−6 ions per atom, respectively. The sizes of the smallest detectable Ag, Au and U metallic nanoparticles are estimated to be 46 nm, 32 nm and 22 nm, respectively. Furthermore, time shifts of the signals of different elements within single droplets were observed. These new results demonstrate the advantage of the temporal resolution of the instrument for studying processes taking place in the plasma on the μs-time scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Cited by
Nanoparticle Size Detection Limits by Single Particle ICP-MS for 40 Elements
Lee, S., Bi, X., Reed, R. B., Ranville, J. F., Herckes, P., & Westerhoff, P. (2014) · Environmental Science & Technology · doi:10.1021/es502422v · Cited by 448
Metadata
- Authors
- Borovinskaya, O., Hattendorf, B., Tanner, M., Gschwind, S., & Günther, D.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 28
- Issue
- 2
- Pages
- 226-233
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2052246818
- Cited by
- 164
- References
- 1
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prototype of a new inductively coupled plasma time-of-flight mass spectrometer providing temporally resolved, multi-element detection of short signals generated by single particles and droplets. https://app.cochat.ai/papers/10.1039/c2ja30227f
- The paper
- Borovinskaya, O., Hattendorf, B., Tanner, M., Gschwind, S., & Günther, D. (2013). A prototype of a new inductively coupled plasma time-of-flight mass spectrometer providing temporally resolved, multi-element detection of short signals generated by single particles and droplets. J. Anal. At. Spectrom. https://doi.org/10.1039/c2ja30227f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.