Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction
The DOI matches its Crossref record.
Abstract
Elemental speciation in cells is significant for metallomics research. In this study, novel methods of (on-chip) magnetic solid phase extraction (MSPE) combined with high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) were proposed for selenium speciation in selenium-enriched yeast cells. An integrated microfluidic chip consisting of reaction, mixing, and extraction units was designed and fabricated for on-chip MSPE. Sulfonated polystyrene-coated magnetic nanoparticles (Fe3O4@PSS MNPs) were prepared as adsorption material for MSPE of selenoamino acids and selenopeptide. The factors affecting the extraction performance of the target selenium species by (on-chip) MSPE-HPLC-ICP-MS were systematically investigated. The analytical performance of the (on-chip) MSPE-HPLC-ICP-MS was evaluated under individual optimal conditions. The limits of detection for five target selenium species were 0.025 μg L−1 to 0.090 μg L−1 and 0.057 μg L−1 to 0.149 μg L−1 for MSPE-HPLC-ICP-MS and on-chip MSPE-HPLC-ICP-MS, respectively. The MSPE-HPLC-ICP-MS method is sensitive, fast, easy-to-operate, and economical. The on-chip MSPE-HPLC-ICP-MS method has the unique advantages of low sample consumption and high integration; thus, it is suitable for selenium speciation in a small number (∼800) of selenium-enriched yeast cells. A Certified Reference Material of SELM-1 yeast was used to validate the accuracy of the developed (on-chip) MSPE-HPLC-ICP-MS methods. The proposed methods were successfully applied to the speciation of selenium in selenium-enriched yeast cells. Analysis of approximately 800 cells by on-chip MSPE-HPLC-ICP-MS revealed that the average amounts of selenocystine (SeCys2) and selenomethionine (SeMet) in a single selenium-enriched yeast cell are in the order of subpicograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic materials as sorbents for metal/metalloid preconcentration and/or separation. A review
Giakisikli, G., & Anthemidis, A. N. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.021 · Cited by 449
Magnetic solid-phase extraction using carbon nanotubes as sorbents: a review
Herrero-Latorre, C., Barciela-García, J., García-Martín, S., Peña-Crecente, R. M., & Otárola-Jiménez, J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.07.046 · Cited by 344
“19 strategy is the on-chip M-SPE method [69-71].”
MethodApplication of functionalized magnetic nanoparticles in sample preparation
Xie, L., Jiang, R., Zhu, F., Liu, H., & Ouyang, G. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7302-6 · Cited by 266
Magnetic solid phase extraction as a valuable tool for elemental speciation analysis
Corps Ricardo, A. I., Abujaber, F., Guzmán Bernardo, F. J., Rodríguez Martín-Doimeadios, R. C., & Ríos, Á. (2020) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2020.e00097 · Cited by 51
Quantification of Methylated Selenium, Sulfur, and Arsenic in the Environment
Vriens, B., Ammann, A. A., Hagendorfer, H., Lenz, M., Berg, M., & Winkel, L. H. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102906 · Cited by 41
“Quantification limits may be further improved depending on the applied air flow and the duration of trapping, the purity of the trapping liquid, or instrumentally by using, for example, hydride generation or additional preconcentration techniques prior to ICP-MS [21,29,44].”
Method
Metadata
- Authors
- Chen, B., Hu, B., He, M., Huang, Q., Zhang, Y., & Zhang, X.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 28
- Issue
- 3
- Pages
- 334
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2054938060
- Cited by
- 64
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.