The DOI matches its Crossref record.
Inkjet-printed graphene-PEDOT:PSS modified screen printed carbon electrode for biochemical sensing
Abstract
In this work, a novel method for electrode modification based on inkjet-printing of electrochemically synthesized graphene-PEDOT:PSS (GP-PEDOT:PSS) nanocomposite is reported for the first time. GP-PEDOT:PSS dispersed solution is prepared for use as an ink by one-step electrolytic exfoliation from a graphite electrode. GP-PEDOT:PSS layers are then printed on screen printed carbon electrodes (SPCEs) by a commercial inkjet material printer (Dimatrix Inc.) and their electrochemical behaviors towards three common electroactive analytes, including hydrogen peroxide (H2O2), nicotinamide adenine dinucleotide (NAD+/NADH) and ferri/ferro cyanide (Fe(CN)63−/4−) redox couples, are characterized. It is found that the oxidation signals for H2O2, NADH and K2Fe(CN)6 of PEDOT:PSS modified and GP-PEDOT:PSS modified SPCEs are ∼2–4 and ∼3–13 times higher than those of unmodified SPCE, respectively. In addition, excellent analytical features with relatively wide dynamic ranges, high sensitivities and low detection limits have been achieved. Therefore, the inkjet-printed GP-PEDOT:PSS electrode is a promising candidate for advanced electrochemical sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional inks and printing of two-dimensional materials
Hu, G., Kang, J., Ng, L. W. T., Zhu, X., Howe, R. C. T., Jones, C. G., Hersam, M. C., & Hasan, T. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00084k · Cited by 569
2D‐Crystal‐Based Functional Inks
Bonaccorso, F., Bartolotta, A., Coleman, J. N., & Backes, C. (2016) · Advanced Materials · doi:10.1002/adma.201506410 · Cited by 446
A manufacturing perspective on graphene dispersions
Johnson, D. W., Dobson, B. P., & Coleman, K. S. (2015) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2015.11.004 · Cited by 440
Methods for the regeneration of nicotinamide coenzymes
Wu, H., Tian, C., Song, X., Liu, C., Yang, D., & Jiang, Z. (2013) · Green Chemistry · doi:10.1039/c3gc37129h · Cited by 382
Wen, Y., & Xu, J. (2017) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.28482 · Cited by 378
Low-cost and flexible printed graphene–PEDOT:PSS gas sensor for ammonia detection
Seekaew, Y., Lokavee, S., Phokharatkul, D., Wisitsoraat, A., Kerdcharoen, T., & Wongchoosuk, C. (2014) · Organic Electronics · doi:10.1016/j.orgel.2014.08.044 · Cited by 373
Self-citationDispersions of Non-Covalently Functionalized Graphene with Minimal Stabilizer
Parviz, D., Das, S., Ahmed, H. S. T., Irin, F., Bhattacharia, S., & Green, M. J. (2012) · ACS Nano · doi:10.1021/nn302784m · Cited by 360
Inkjet deposition of liquid-exfoliated graphene and MoS2nanosheets for printed device applications
Finn, D. J., Lotya, M., Cunningham, G., Smith, R. J., McCloskey, D., Donegan, J. F., & Coleman, J. N. (2014) · J. Mater. Chem. C · doi:10.1039/c3tc31993h · Cited by 292
Graphene-based wearable sensors
Qiao, Y., Li, X., Hirtz, T., Deng, G., Wei, Y., Li, M., Ji, S., Wu, Q., Jian, J., Wu, F., et al. (2019) · Nanoscale · doi:10.1039/c9nr05532k · Cited by 158
Metadata
- Authors
- Sriprachuabwong, C., Karuwan, C., Wisitsorrat, A., Phokharatkul, D., Lomas, T., Sritongkham, P., & Tuantranont, A.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 22
- Issue
- 12
- Pages
- 5478
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2044153614
- Cited by
- 190
- References
- 0
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.