The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reduced graphene oxide and activated carbon composites for capacitive deionization
Abstract
In this paper, reduced graphene oxide (RGO) and activated carbon (AC) composites (GAC) have been synthesized by a facile chemical method for the capacitive removal of salt ions from brackish water. The as-prepared composites have been characterized by scanning electron microscopy, N2 adsorption–desorption and cyclic voltammetry. The GAC composite with 20 wt% graphene (GAC-20) exhibits the best electrochemical performance among all the samples, with a specific capacitance of 181 F g−1. The electrosorption capacity of the GAC-20 electrode is found to be much higher than that of the AC electrode, indicating that RGO can serve as a flexible bridge to form a “plane-to-point” (RGO-to-AC) conducting network, which is beneficial for decreasing the aggregation of AC particles, and improves the electron transfer within the composite electrode. GAC composite should be a promising candidate as an electrode material for capacitive deionization (CDI) applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The chemistry of graphene oxide
Dreyer, D. R., Park, S., Bielawski, C. W., & Ruoff, R. S. (2010) · Chem. Soc. Rev. · doi:10.1039/b917103g · Cited by 11,653
Anderson, M. A., Cudero, A. L., & Palma, J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.02.012 · Cited by 943
Cited by
Review on the science and technology of water desalination by capacitive deionization
Porada, S., Zhao, R., van der Wal, A., Presser, V., & Biesheuvel, P. M. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.03.005 · Cited by 2,152
Water desalination via capacitive deionization: what is it and what can we expect from it?
Suss, M. E., Porada, S., Sun, X., Biesheuvel, P. M., Yoon, J., & Presser, V. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00519a · Cited by 1,712
Environmental applications of graphene-based nanomaterials
Perreault, F., Fonseca de Faria, A., & Elimelech, M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00021a · Cited by 1,528
Porada, S., Borchardt, L., Oschatz, M., Bryjak, M., Atchison, J. S., Keesman, K. J., Kaskel, S., Biesheuvel, P. M., & Presser, V. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42209g · Cited by 571
Graphene-based composites for electrochemical energy storage
Wang, B., Ruan, T., Chen, Y., Jin, F., Peng, L., Zhou, Y., Wang, D., & Dou, S. (2020) · Energy Storage Materials · doi:10.1016/j.ensm.2019.08.004 · Cited by 530
Metadata
- Authors
- Li, H., Pan, L., Nie, C., Liu, Y., & Sun, Z.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 22
- Issue
- 31
- Pages
- 15556
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2146867288
- Cited by
- 243
- References
- 2
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced graphene oxide and activated carbon composites for capacitive deionization. https://app.cochat.ai/papers/10.1039/c2jm32207b
- The paper
- Li, H., Pan, L., Nie, C., Liu, Y., & Sun, Z. (2012). Reduced graphene oxide and activated carbon composites for capacitive deionization. Journal of Materials Chemistry. https://doi.org/10.1039/c2jm32207b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.