The DOI matches its Crossref record.
Programmable large area digital microfluidic array with integrated droplet sensing for bioassays
Abstract
We describe a new device concept for digital microfluidics, based on an active matrix electrowetting on dielectric (AM-EWOD) device. A conventional EWOD device is limited by the number of electrical connections that can be made practically, which restricts the number and type of droplet operations. In an AM-EWOD, the patterned electrodes of a conventional EWOD device are replaced by a thin film transistor (TFT) array, as found in a liquid crystal display (LCD), facilitating independent control of each electrode. The arrays can have many thousand individually addressable electrodes, are fully reconfigurable and can be programmed to support multiple simultaneous operations. Each element is 210 μm × 210 μm in size and contains a circuit that measures the electrical impedance of the liquid above it. This is used to determine the presence and size of a droplet, a method that can improve assay reliability and accuracy. This sensor provides feedback, error detection and closed loop control of an assay sequence. We describe the design, fabrication and testing of a 64 × 64 format AM-EWOD device with impedance sensor functionality. A colorimetric assay is implemented on the device and used to measure glucose in human blood serum. Results are compared with the same assay performed on a microtitre plate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
Current commercialization status of electrowetting-on-dielectric (EWOD) digital microfluidics
Li, J., & Kim, C.-J. “. (2020) · Lab on a Chip · doi:10.1039/d0lc00144a · Cited by 257
Hepatic organoids for microfluidic drug screening
Au, S. H., Chamberlain, M. D., Mahesh, S., Sefton, M. V., & Wheeler, A. R. (2014) · Lab on a Chip · doi:10.1039/c4lc00531g · Cited by 162
Metadata
- Authors
- Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 18
- Pages
- 3305
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1987919377
- Cited by
- 211
- References
- 0
- FWCI
- 11.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Programmable large area digital microfluidic array with integrated droplet sensing for bioassays. https://app.cochat.ai/papers/10.1039/c2lc40273d
- The paper
- Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H. (2012). Programmable large area digital microfluidic array with integrated droplet sensing for bioassays. Lab on a Chip. https://doi.org/10.1039/c2lc40273d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.