The DOI matches its Crossref record.
Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing
Abstract
To the best of our knowledge, this is the first report on paper-based devices for automating the sequential multistep procedures of a sandwich-type enzyme-linked immunosorbent assay (ELISA) that require only a single-step application of the sample solution. The device was based on a piece of nitrocellulose (NC) membrane with specially designed channels, where all the reagents are applied at different locations in order to control the fluid travel to the detection region. The inkjet printing method, a simple and low-cost process, was used to create the flow channel and device barrier patterns. The fabricated barrier was found to be an efficient boundary for the liquid along the printed design in the NC membrane, enabling direct control of the reagent flow time. ELISA results were obtained with a single-step sample application. The developed devices (so-called automated paper-based devices) provided a simple procedure for the sandwich ELISA, while reducing assay time and reagent consumption. Colorimetric results were measured using digital camera imaging with software processing. The capability of the method developed herein was successfully used to determine the levels of human chorionic gonadotropin (hCG) by ELISA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Metadata
- Authors
- Apilux, A., Ukita, Y., Chikae, M., Chailapakul, O., & Takamura, Y.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 1
- Pages
- 126-135
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2097639735
- Cited by
- 230
- References
- 0
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing. https://app.cochat.ai/papers/10.1039/c2lc40690j
- The paper
- Apilux, A., Ukita, Y., Chikae, M., Chailapakul, O., & Takamura, Y. (2013). Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing. Lab Chip. https://doi.org/10.1039/c2lc40690j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.