Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A highly selective red-emitting FRET fluorescent molecular probe derived from BODIPY for the detection of cysteine and homocysteine: an experimental and theoretical study

Shao, Jingyin, Sun, Haiyang, Guo, Huimin, Ji, Shaomin, Zhao, Jianzhang, Wu, Wenting, Yuan, Xiaolin, Zhang, Chunlei, James, Tony D.·2012·Chem. Sci.

Abstract

A red-emitting BODIPY-based fluorescent-resonance-energy-transfer (FRET) molecular probe 1 for selective detection of cysteine and homocysteine was designed. The fluorescence OFF–ON switch is triggered by cleavage of the 2,4-dinitrobenzensulfonyl (DNBS) unit from the fluorophore by thiols. The FRET energy donor (λabs = 498 nm, λem = 511 nm) is a parent BODIPY moiety and the energy acceptor is based on 4-hydroxylstyryl BODIPY moiety (λabs = 568 nm, λem = 586 nm). The unique C–C linker between the energy donor and acceptor was established using a Suzuki cross-coupling reaction. A polyether chain was also introduced into the probe to improve solubility in aqueous solution. While probe 1 itself is non-fluorescent, in the presence of cysteine or homocysteine a red emission at 590 nm is switched on (excitation at 505 nm), producing a pseudo-Stokes shift of up to 77 nm, which is in stark contrast to the small Stokes shift (ca. 10 nm) observed for typical BODIPY dyes. Excitation of the energy donor leads to the red emission from the acceptor of the probe, and demonstrates a high energy transfer efficiency. The probe was used for in vivo fluorescent imaging of cellular thiols. The fluorescence sensing mechanism of the probe and the photophysical properties of the fluorescent intermediates were fully rationalized by DFT calculations. The lack of fluorescence of probe 1 is attributed to the dark excited state S1 (oscillator strength f = 0.0007 for S0 → S1, based on the optimized S1 state geometry), which is due to the electron sink effect of the DNBS moiety. Cleavage of the DNBS moiety from the fluorophore by thiols re-establishes the emissive S1 state of the fluorophore (f = 1.4317 for S0 → S1), thus the red emission can be observed in the presence of thiols (fluorescence is turned on). The FRET effect of the probe was rationalized by DFT calculations which indicated that upon excitation into the S4 excited state (localized on the energy donor unit), the S1 state (localized on the energy acceptor, i.e. styryl-BODIPY) is populated via internal conversion (IC), thus red emission from the styryl-BODIPY energy acceptor is observed (Kasha's rule).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c2sc00762b

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 265

Metadata

Authors
Shao, J., Sun, H., Guo, H., Ji, S., Zhao, J., Wu, W., Yuan, X., Zhang, C., & James, T. D.
Venue
Chem. Sci.
Published
2012
Volume
3
Issue
4
Pages
1049-1061
ISSN
  • 2041-6520 (ISSN-L)
  • 2041-6539
OpenAlex
W2083670401
Cited by
265
References
1
FWCI
12.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.